background image

13

APPENDIX A, ADDITIONAL MicroSentry™ FEATURES

Information Menu:

The following features are available on the Information Menu.
• 

Current Temperature

• 

Maximum Stored Temperature

• 

Minimum Stored Temperature

• 

Total Operating Time Of The Condenser

• 

Keypad Lockout

To access the Information Menu Press “SET” button momentarily 
and release.

Once in the information menu, the WARMER and COLDER keys 
may be used to scroll through the information menu.  Addition

-

ally, pressing and releasing the SET key will advance the informa

-

tion menu.
The information menu will automatically exit after several sec

-

onds with no key presses.

                       Current Interior Temperature (tI):

 Press and 

                       hold the “SET” key to display the current inte-
                       rior temperature.

                       Maximum Stored Temperature (thi): Maxi-

                       mum stored temperature is the maximum 
                       temperature refrigerator has achieved since tem

-

perature set point was entered. Press and hold the “SET” key 
to display the maximum temperature stored. The data can be 
cleared by pressing “SET” and “ON/OFF” simultaneously while 
the value is displayed. NOTE: It is normal for refrigerator tem

-

perature to fluctuate from set point by several degrees.

                      Minimum Stored Temperature (tLO): Mini-

                      mum stored temperature is the minimum 
                      temperature refrigerator has achieved since temper

-

ature set point was entered. Press and hold the “SET” key to dis

-

play the minimum temperature stored. The data can be cleared 
by pressing “SET” and “ON/OFF” simultaneously while the value 
is displayed. NOTE: It is normal for refrigerator temperature to 
fluctuate from set point by several degrees.

                     Total Operating Time of the Condenser Since 
                     the Last Cleaning (cnd):

 Press and hold the 

                     “SET” key to display the total operating hours of the 
compressor since the last cleaning. The control stores the total 
operating hours of the compressor to determine the volume of 
air that has moved across the condenser coils.  This number is 
displayed in weeks. A reminder is displayed when a cleaning is 
recommended (see Alarm Codes). The recommended cleaning 
period is the equivalent of one year of air volume. The data can 
be cleared by pressing the “SET” and “ON/OFF” keys simultane

-

ously while the value is displayed.

 

 

 

 

 

 

 

 

 

 

 

                         Keypad Lockout Feature (Loc):

 This feature 

                         is useful for prohibiting changes in the 
                         temperature set point or accidentally turning the 
unit off. Press and hold the “SET” key to display the cur-

rent “Loc” setting. If “No”                     is displayed, Lock

out is OFF and all keys are enabled. If “Yes” 
is displayed, Lockout is ON and the “ON/OFF”, “WARMER”, and 
“COLDER” keys are disabled. However, the key tones remain 
enabled. While holding the “SET” key, press the “WARMER” or 
“COLDER” key to select the desired state.  Release the “SET” key 
to confirm the selection.  

NOTE: The Information/Lockout Key “SET” remains enabled 
regardless of the “Loc” setting.

 

 

 

 

 

 

 

 

 

 

 

NOTE

Summary of Contents for 61WCM (Marvel)

Page 1: ...Installation Operation and Maintenance Instructions Refrigerated Wine Cellar 61WCM ...

Page 2: ...nser air flow Cleaning the cabinet Cleaning the interior Cleaning the wine shelves Cleaning the door gasket Replacing the light bulb Troubleshooting Guide Obtaining Service Household Product Warranty Appendix A additional MicroSentry features 2 2 2 3 3 3 3 3 3 4 5 6 6 7 8 9 9 9 9 9 9 9 10 11 12 13 is committed to building a quality product in an environmentally friendly manner Our processes are ti...

Page 3: ... of Purchase Dealers name and address The model number and serial number can be found on the se rial plate which is located inside the wine cellar on the left side toward the top of the liner Warranty Registration Help Prevent Tragedies Child entrapment and suffocation are not problems of the past Junked or abandoned refrigerators are still dangerous even if they sit out for just a few days If you...

Page 4: ...dance with the Na tional Electrical Code and applicable local codes and ordinances see Figure 2 If the circuit does not have a grounding type re ceptacle it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances The third ground prong should not under any circumstances be cut...

Page 5: ...s Your MicroSentry refrigerator control will monitor refrigerator function and alert you with a series of audible and visual alarms Door Ajar Alarm If the door has been left open for over five 5 minutes the alarm will sound in one 1 second intervals The display panel will flash do and the LED light will be a steady amber color This will stop as soon as the door is closed High and Low Temperature A...

Page 6: ...the condition that caused the alarm continues the alarm code will continue to flash and will sound for 20 seconds every 60 minutes Turning Refrigerator Off To turn refrigerator off press and hold ON OFF button for three 3 seconds OFF will appear on the display Additional MicroSentry Features Refer to Appendix A for details on additional features available ...

Page 7: ... prong grounded receptacle is required Power outlet can be located in the back wall behind unit Add 1 to depth for thickness of plug or recess outlet 1 into the wall Power outlet can also be installed in adjacent cabinetry with a cutout for routing of power cord Follow all local building codes when installing electrical and unit Product weight 130 lbs 59 1 kg 23 7 8 60 66cm 3 to 3 1 4 7 62 to 8 26...

Page 8: ... Position your wines accordingly and REMEMBER TO TURN OFF THE LIGHT WHEN IT IS NO LONGER NEEDED Keep wines that you plan to use for everyday drinking and enter taining on the front half of the racks where labels are completely visible Place wines for aging or longer term storing in the rear Pull out Racks The four 4 pull out wine racks may be pulled out approximately seven and a half 7 5 inches to...

Page 9: ... Use a 5 32 allen wrench for this procedure See Figure 7 below Figure 7 Hinge adapter screws loosen these to adjust door on the top and bottom of the door Top hinge pin re move to remove the door Door must be parallel to top and sides of refrigerator 9 32 7 1mm NOTE For door closer to work properly it is necessary to main tain a minimum space of 9 32 7 1mm between door and cabinet flange as shown ...

Page 10: ...CORD BEFORE ATTEMPTING LIGHT BULB REPLACEMENT Failure to do so may result in an electrical shock that could severely injure you The 61WCM uses one 15 watt incandescent light bulb to il luminate the interior of the wine cellar The light bulb is a very reliable electrical component but should it not function prop erly please call the dealer where you purchased your wine cellar from for a replacement...

Page 11: ...r to page 3 for leveling instructions Verify the door is aligned properly refer to page 8 for instructions Noise or Vibration Unit not level Level unit see Leveling Legs on page 3 Unit will not run Unit turned off Power cord not plugged in No power at outlet Turn unit on See Starting your Re frigerator on page 4 Plug in power cord Check house circuit Before You Call for Service If the unit appears...

Page 12: ... product is outside the first year warranty period AGA MARVEL Customer Service can provide recommendations of service centers in your area A listing of authorized service centers is also available at www agamarvel com under the service and support section In all correspondence regarding service be sure to give the model number serial number and proof of purchase Try to have information or descript...

Page 13: ... expiration of the one year limited warranty AGA MARVEL will supply replacement parts for the hermetically sealed refrigeration system which consists of the compressor condenser drier accumulator bypass valve con necting tubing and the evaporator that are proven to be defec tive due to workmanship or materials subject to the conditions and exclusions below The above warranties do not cover Shippin...

Page 14: ... entered Press and hold the SET key to dis play the minimum temperature stored The data can be cleared by pressing SET and ON OFF simultaneously while the value is displayed NOTE It is normal for refrigerator temperature to fluctuate from set point by several degrees Total Operating Time of the Condenser Since the Last Cleaning cnd Press and hold the SET key to display the total operating hours of...