background image

INSTALLING THE ANTI-TIP DEVICE

4

A cabinet “anti–tip” device is mounted to the back of your refrig

-

erated drawer unit. If your installation is a built – in under coun

-

ter application with a counter-top directly above the unit this 
item can be removed, it does not need to be applied. If your unit 
is a freestanding application with no counter-top directly above 
the top of the unit, you must apply this feature to prevent the 
unit from tipping forward when the drawers are pulled out. The 
anti–tip device is installed on the back of the unit. The anti–tip 
device reduces the chance of personal injury as well as property 
damage when properly installed between the back of the unit 
and the adjacent wall. Please see the following instructions for 
installing the anti-tip device.

1.      Push the unit against the wall so the anti-tip  
         bracket is flush to the wall adjacent to the back 
         panel. Level the unit with the leveling legs provided
         in the cabinet bottom. (See Leveling Legs on 
         page 3).    
2.      Using a pencil and the bracket as a template, trace
         the bracket on the wall, making sure 2 of the screw
         holes are aligned with a stud in the wall.
3.      Pull the unit away from the wall.
4.      Remove the screws that connect the upper and
         lower sections of the anti-tip bracket.
5.      Place the bracket on the wall and mark and drill
         3/16” diameter pilot holes for the provided ¼” lag 
         screws. Mount the lower section to the wall with the
         ¼” lag screws.
6.      Move the unit into place aligning the screw holes
         between the upper and lower brackets and secure
         with the screws removed in step 4. 

Anti - Tip Device

Anti-Tip device

Figure 3

To Wall

To Refrigerated 

Drawer Cabinet

Remove these screws to separate 
upper and lower sections of anti-tip 
bracket.

Figure 4

1/4” Lag screws 
into wall

Summary of Contents for 60RDE

Page 1: ...Installation Operation and Maintenance Instructions Refrigerated Drawer Model 60RDE...

Page 2: ...y Important Safety Instructions Warnings and safety instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur Common sense caution and care must...

Page 3: ...N DAMAGED MERCHANDISE TO THE MANUFAC TURER FILE THE CLAIM WITH THE RETAILER Help Prevent Tragedies Child entrapment and suffocation are not problems of the past Junked or abandoned refrigerators are s...

Page 4: ...l Code and applicable local codes and ordinances see Figure 2 If the circuit does not have a grounding type re ceptacle it is the responsibility and obligation of the customer to exchange the existing...

Page 5: ...evice 1 Push the unit against the wall so the anti tip bracket is flush to the wall adjacent to the back panel Level the unit with the leveling legs provided in the cabinet bottom See Leveling Legs on...

Page 6: ...Requirements 115 volts 3 3 amps running max 15 amp dedicated circuit required 3 prong grounded receptacle required Power outlet can be located in the back wall behind unit Add 1 to depth for thickness...

Page 7: ...ture variance at different locations within the cabinet Load Your Appliance Load your appliance with your desired items Please note that it may take up to 24 hours for your refrigerator to reach the d...

Page 8: ...h red This will warn you that your contents have seen temperatures that may not be con ducive for long term storage This alarm can be reset by pressing the ON OFF button Power Failure If your unit exp...

Page 9: ...key while pressing the F C key four 4 times in seven 7 seconds The display will flash SA seven 7 times then the unit will enter Sabbath Mode The display audible alarms LED and lights will be disabled...

Page 10: ...ag nostics Mode will automatically exit after five 5 minutes of no keypad entry Display Error Code Reference The microprocessor in the control continually monitors critical refrigeration sys tem compo...

Page 11: ...inet The painted cabinet can be washed with either a mild soap and water and thoroughly rinsed with clear water NEVER use abra sive scouring cleaners Interior Wash interior compartment with mild soap...

Page 12: ...r optimum storage and organization of storage space P N 42245444 for 60RDE upper drawer P N 42245445 for 60RDE lower drawer For further information on available options visit the AGA MARVEL web site a...

Page 13: ...ot go out when drawer is closed Drawer not activating light switch Unit not level level unit See page 3 leveling legs Noise or Vibration Unit not level Level unit see Leveling Legs on page 3 Unit will...

Page 14: ...the service and support section In all correspondence regarding service be sure to give the model number serial number and proof of purchase Try to have information or description of nature of the pro...

Page 15: ...l supply replacement parts for the hermetically sealed refrigeration system which consists of the compressor condenser drier accumulator bypass valve con necting tubing and the evaporator that are pro...

Page 16: ...notice Such revisions do not entitle the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www agamarvel com P O Box 400 1260 E VanDe...