Refer to the Parts List 

Previous Page 

for Part Numbers. 

Plumbing Detail 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line. 

Proper care and maintenance will prolong the life of your sprayer. 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half way with clean water. Start the pump and allow the water to 

pump through the entire plumbing system and nozzles. Drain and then refill half full, add the recommended amount of a good quality tank cleaner, 

such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  

Turn pump on and circulate through system for 15 minutes and then spray out through boom and handgun nozzles. Refill sprayer half way with clean 

water and repeat. Follow the chemical manufacturer’s disposal instructions of all wash or rinsing water.  

If boom or handgun nozzles need cleaning, remove them from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick 

if necessary. Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tips before 

storing. 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS flush the pump as instructed 

after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s instructions on disposal 

of all waste water from the sprayer.

 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV antifreeze through the system. This will keep internal parts lubricated, protect against 

corrosion and keep the unit from freezing. 

Note: RV antifreeze is non

-

toxic and biodegradable and generally safer for the environment than automotive 

antifreeze.

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough pink RV antifreeze 

into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system, including the pressure adjust 

(bypass) line. Make sure to operate the boom and handgun until you see pink fluid spraying from the nozzles. Leave any remaining antifreeze in the 

tank. Before your next usage, rinse the antifreeze from the sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage parts of the sprayer. 

Pumping the antifreeze through the system will displace the water and help prevent this damage. 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and flush water properly. 

Intak

e Lin

Bypas

s Line

 

Summary of Contents for FSSS-60-12V

Page 1: ...n Resistant Polyethylene Tank 12 Volt Diaphragm Pump 4 0 GPM 45 PSI Pistol Grip Handgun 15 Ft Handgun Hose Optional Trailer Boom Kits Available General Information Thank you for purchasing this product The purpose of this manual is to assist you in operating and maintaining your skid sprayer IMPORTANT This sprayer comes with an On Off shut off valve located on the inlet line just before the pump Y...

Page 2: ...ons occurs Boom valve is opened to broadcast spray with the boom if applicable Pressure adjust valve is opened to re circulate solution back into the tank Initially begin spraying by closing the Pressure Adjust valve and opening the boom line valve if applicable Detail A This will enable the air in the line to be eliminated purged through all the tips while building pressure When everything tests ...

Page 3: ...ch assembly will need to be replaced Check the fuse if applicable Check for low voltage at the power supply Pump does not prime Check for air leaks in supply line Check for debris in the valve assembly Check for defective valve assembly Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Pulsating flow surging Check for defective switch assembly Ch...

Page 4: ...Page 4 See Plumbing Detail Next Page Exploded View Parts List FSSS 60 12V 5301445 BLK 5301445 BLU ...

Page 5: ...untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical manufacturer s instructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated pro...

Page 6: ... notice to Ag Spray Equipment of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes neces sary at the following address Ag Spray Equipment 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Ag Spray Equipment or an authorized dealer within a reasonable period of time For more information about this Li...

Reviews: