![AG Neovo DR-17G User Manual Download Page 9](http://html1.mh-extra.com/html/ag-neovo/dr-17g/dr-17g_user-manual_2865216009.webp)
9
SAFETY INFORMATION
ESD declaration statement
There was flickered disturbance on the screen during the test, but could self-recover after the test.
(This permissive loss of performance was met the specification of EUT.)
DIP declaration statement
The EUT reset during the test, but could self-recover after the test.
(This permissive loss of performance was met the specification of EUT.)
Recommended separation distances between portable and mobile RF communications equipment
and the DR-17G and DR-22G
The DR-17G and DR-22G is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the DR-17G and DR-22G can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile RF
communications equipment (transmitters) and the DR-17G and DR-22G as recommended below, according
to the maximum output power of the communications equipment.
Rated maximum output
power of transmitter (W)
Separation distance according to frequency of transmitter (m)
150kHz to 80MHz
1.2
80MHz to 800MHz
1.2
800MHz to 2.5GHz
2.
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance
“d” in meters (m) can be estimated using the equation applicable to the frequency of the transmitter,
where “P” is the maximum output power rating of the transmitter in watts (W) according to the transmitter
manufacturer.
NOTE 1
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
Cable length
Power Cord : Accessory
1.8m