14
©Copyright LOTRONIC 2018
Figure 2 DMX Chart
CH1
DMX Value
Volume/Fan
5-255
Volume 5%-100%
Fan 100%
0-4
Volume 0%
Fan 5%
CH1
CH2
DMX Value
Volume
DMX Value
Fan
5-255
5%-100%
16-255
6%-100%
0-4
0
0-15
5%
1 CH
2 CH
4 CH
CH1
CH2
CH3
CH4
DMX Value Volume
DMX Value Fan
DMX Value Interval
DMX Value Duration
5-255
5%-100%
16-255
6%-100%
250-255
250s
250-255
250s
0-4
0
0-15
5%
5-249
5-249s
5-249
6-249s
0-4
0s
0-5
5s
**s=seconds.
**Interval =0 means constant fog.
** When the faze state is off (volume =0), the timer does not work, the LCD display of the
machine shows values of interval and duration which are the parameters set by the DMX console;
when the faze state is on (volume=5%-100%), the timer works, the interval and duration values
shows by LCD display are decreased by second, this process will always be cycled.