MOUNTING

 

Orientation

 

This

 

fixture

 

may

 

be

 

mounted

 

in

 

any

 

position,

 

provided

 

there

 

is

 

adequate

 

room

 

for

 

ventilation

 

When

 

selecting

 

installation

 

location,

 

take

 

into

 

consideration

 

lamp

 

replacement

 

access

 

and

 

routine

 

maintenance.

   

Safety

 

cables

 

must

 

always

 

be

 

used.

 

Never

 

mount

 

in

 

places

 

where

 

the

 

fixture

 

will

 

be

 

exposed

 

to

 

rain,

 

high

 

humidity,

 

extreme

 

temperature

 

changes

 

or

 

restricted

 

ventilation.

 

If

 

the

 

external

 

flexible

 

cable

 

or

 

cord

 

of

 

this

 

light

 

is

 

damaged,

 

it

 

shall

 

be

 

exclusively

 

replaced

 

by

 

the

 

manufacturer

 

or

 

his

 

service

 

agent

 

or

 

a

 

similar

 

qualified

 

person

 

in

 

order

 

to

 

avoid

 

a

 

hazard.

 

Make

 

sure

 

the

 

installation

 

position

 

is

 

stable

 

before

 

you

 

fix

 

the

 

light.

 

When

 

the

 

light

 

is

 

reverse

 

hanging,

 

make

 

sure

 

the

 

light

 

will

 

not

 

fall

 

from

 

the

 

truss,

 

use

 

the

 

safety

 

cable

 

go

 

through

 

the

 

truss

 

and

 

bracket

 

of

 

the

 

light

 

as

 

a

 

supporting,

 

to

 

avoid

 

the

 

light

 

to

 

fall

 

down.

 

There

 

is

 

no

 

entrance

 

to

 

the

 

work

 

area

 

during

 

mounting.

 

Periodically

 

check

 

if

 

the

 

safety

 

cable

 

has

 

fretted

 

away

 

or

 

clamp

 

is

 

loosened.

 

We

 

will

 

not

 

take

 

any

 

responsibility

 

for

 

damages

 

caused

 

by

 

a

 

badly

 

installed

 

unit.

 

 

Power

 

Supply

 

and

 

Signal

 

Cable

 

Connection

 

1.

 

Mains

 

Power

 

connection

 

The

 

exclusive

 

plug

 

should

 

be

 

used

 

between

 

the

 

connection

 

of

 

unit

 

and

 

power.

 

Please

 

ensure

 

that

 

the

 

rated

 

voltage

 

and

 

frequency

 

are

 

accordance

 

with

 

the

 

power

 

supply.

 

The

 

required

 

input

 

voltage

 

and

 

frequency

 

are:

 

100

240VAC

 

We

 

suggest

 

that

 

every

 

light

 

has

 

an

 

independent

 

switch

 

so

 

that

 

you

 

can

 

turn

 

on

 

or

 

turn

 

off

 

the

 

light

 

randomly.

 

Note:

 

the

 

ground

 

wire

 

(yellow/green

 

double

color

 

wire)

 

must

 

be

 

safely

 

connected,

 

the

 

electrical

 

installation

 

must

 

be

 

in

 

accordance

 

with

 

the

 

related

 

standards

 

CAUTION

:

 

When

 

installing

 

the

 

device,

 

make

 

sure

 

there

 

is

 

no

 

highly

 

inflammable

 

material

 

within

 

a

 

distance

 

of

 

min.5m!

 

 

2.

 

Connection

 

of

 

Signal

 

Cable

 

You

 

can

 

use

 

the

 

3

pin

 

XLR

 

cable

 

to

 

connect

 

the

 

output

 

socket

 

of

 

the

 

master

 

and

 

the

 

input

 

socket

 

of

 

the

 

slave

 

light.

 

Connect

 

the

 

DIGITAL

 

OUT

 

socket

 

of

 

the

 

master

 

and

 

the

 

IN

 

socket

 

of

 

the

 

slave

 

light,

 

then,

 

connect

 

the

 

OUT

 

socket

 

to

 

the

 

IN

 

socket

 

of

 

the

 

next

 

light.

 

Ordinal

 

to

 

connect

 

all

 

the

 

lights

 

as

 

below:

 

IN

O U T

IN

O U T

O U T

IN

1

2

3

D

M

X

 

 

I

N

D

M

X

 

 

O

U

T

 

The

 

connection

 

between

 

the

 

output

 

of

 

master

 

and

 

input

 

of

 

product,

 

it’s

 

available

 

to

 

use

 

the

 

3

 

pins

 

XLR

 

cable

 

which

 

provided

 

by

 

the

 

manufacturer.

 

Signal

 

cable

 

from

 

the

 

DMX

 

output

 

of

 

the

 

controller

 

to

 

the

 

input

 

of

 

the

 

first

 

master

 

light,

 

and

 

connect

 

to

 

the

 

DMX

 

input

 

of

 

second

 

slave

 

light

 

from

 

the

 

DMX

 

output

 

of

 

the

 

first

 

master

 

light,

 

analogously,

 

till

 

connected

 

all

 

the

 

slave

 

lights,

 

and

 

insert

 

the

 

last

 

connector

 

to

 

the

 

output

 

of

 

the

 

final

 

light.

 

(Notice:

 

the

 

diameter

 

of

 

core

 

of

 

every

 

cable

 

should

 

be

 

0.5mm

 

at

 

least,

 

double

 

core

 

shelter

 

cable

 

should

 

be

 

used).The

 

signal

 

connecting

 

must

 

use

 

the

 

attached

 

3

 

pins

 

XLR

 

cable.

 

Notice,

 

all

 

the

 

internal

 

lead

 

wire

 

of

 

the

 

3

 

pins

 

XLR

 

cable

 

should

 

not

 

touch

 

to

 

each

 

other

 

or

 

connect

 

to

 

the

 

connector.

 

 

A

 

DMX

 

signal

 

terminator

 

is

 

recommended

 

on

 

the

 

last

 

unit

 

of

 

the

 

chain.

 

DMX

 

terminator

 

is

 

a

 

XLR

 

connector

 

with

 

a

 

120

Ω 

resistor

 

between

 

the

 

pin

 

2

 

and

 

pin

 

3

 

of

 

the

 

XLR

 

connector

   

 

 

 

 

 

 

Summary of Contents for IPAR 518

Page 1: ...013 IPAR 518 Page 1 O OU UT TD DO OO OR R L LE ED D P PR RO OJ JE EC CT TO OR R P PR RO OJ JE EC CT TE EU UR R A A L LE ED DS S E EX XT TE ER RI IE EU UR RE E IPAR 518 15 1662 GB INSTRUCTION MANUAL F...

Page 2: ...ectric shock when touching live wired 2 Never look directly into the light source as sensitive persons may suffer an epileptic shock 3 Please be aware that damages caused by manual modifications to th...

Page 3: ...dependent switch so that you can turn on or turn off the light randomly Note the ground wire yellow green double color wire must be safely connected the electrical installation must be in accordance w...

Page 4: ...White Strobe Press UP DOWN to choose the value 0 to 255 for level of each color and 0 to 20 for frequency of strobe Press MENU back to the main menu Key code UP DOWN UP DOWN ENTER UP Use to choose ope...

Page 5: ...y edit function Press MENU Back To The Main Menu RUN FUNCTION DMX M S Choose RUN and press ENTER Press UP DOWN to choose DMX or SLAV DMX mode or master slave mode Press MENU back to the main menu DMX...

Page 6: ...nd press ENTER Press UP DOWN to choose 1 255 value EDIT FUNCTION Choose EDIT and press ENTER Press ENTER to choose the parameter values Press UP DOWN to choose program scene or parameters values red R...

Page 7: ...ving please cut off the power and receive again REST To load the factory setup Press ENTER and do the key code UP DOWN UP DOWN then press ENTER ID ID address setting Press ENTER press UP DOWN to choos...

Page 8: ...nel 7 is used to select between 11 temperature of white color CAL2 FUNCTION COLOR DEVIATION CORRECTING SETTING Choose CAL2 then press ENTER to RGBW Press ENTER to choose Red Green Blue White Press UP...

Page 9: ...RED 0 GREEN 100 BLUE UP 90 109 RED UP GREEN 0 BLUE 100 110 129 RED 100 GREEN 0 BLUE DOWN 130 149 RED 100 GREEN 0 BLUE UP 150 169 RED DOWN GREEN DOWN BLUE 100 170 200 RED 100 GREEN 100 BLUE 100 WHITE...

Page 10: ...d Dim 6 175 199 Non linear dimming speed Dim 7 200 224 Non linear dimming speed Dim 8 225 255 Non linear dimming speed Dim 9 12 0 Whole ID address controlled 1 255 The same ID address controlled AR2 d...

Page 11: ...99 Non linear dimming speed Dim 7 200 224 Non linear dimming speed Dim 8 225 255 Non linear dimming speed Dim 9 AR3 d CHANNEL MODE CHANNEL VALUE FUNCTION 1 0 255 MASTER DIM 2 0 255 RED 3 0 255 GREEN 4...

Page 12: ...quent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents CAUTION Disconnect from mains before starting maintenance operation Cleaning and Using Frequency of Produc...

Page 13: ...orsqu il n est pas utilis ou avant de le nettoyer Ne tirez que sur la fiche jamais sur le cordon Lorsque le cordon d alimentation ou un coupleur d appareil est utilis comme dispositif de d connexion c...

Page 14: ...vu qu il y ait suffisamment d espace pour assurer une ventilation suffisante Lorsque vous installez l appareil choisissez un emplacement qui permet d acc der facilement l appareil afin d effectuer l e...

Page 15: ...du c ble double blindage Le diam tre du conducteur de chaque c ble doit tre d au moins 0 5mm PANNEAU DE CONTROLE MENU ENTER UP DOWN MENU DESCRIPTION FONCTION STAT MODE MANUEL S lectionnez STAT puis p...

Page 16: ...AT10 ne sont pas modifiables les programmes PR01 PR10 sont modifiables dans le menu EDIT Appuyez sur MENU pour revenir au menu principal FONCTION RUN MODE MA TRE ESCLAVE S lectionnez RUN puis appuyez...

Page 17: ...ONCTION ID ADRESSE ID S lectionnez ID puis appuyez sur ENTER Appuyez sur UP DOWN pour s lectionner la valeur ID 1 255 FONCTION EDIT EDITION PROGRAMME S lectionnez EDIT puis pressez ENTER Appuyez sur E...

Page 18: ...chargement est termin REST Reset Code de s curit UP DOWN UP DOWN ENTER ID Adresse ID appuyez sur ENTER puis appuyez sur UP DOWN pour choisir ON pour autoriser l utilisation des adresse ID ou OFF pour...

Page 19: ...G le canal 7 permet d appeler 11 niveaux de blancs FONCTION CAL2 BALANCE RGBW S lectionnez CAL2 puis appuyez sur ENTER pour entrer dans le menu RGBW Appuyez sur ENTER pour choisir le rouge R le vert G...

Page 20: ...MAX 70 89 ROUGE 0 VERT 100 BLEU MAX 90 109 ROUGE MAX VERT 0 BLEU 100 110 129 ROUGE 100 VERT 0 BLEU MIN 130 149 ROUGE 100 VERT 0 BLEU MAX 150 169 ROUGE MIN VERT MIN BLEU 100 170 200 ROUGE 100 VERT 100...

Page 21: ...199 Vitesse dimmer non lin aire Dim 7 200 224 Vitesse dimmer non lin aire Dim 8 225 255 Vitesse dimmer non lin aire Dim 9 12 0 Toutes les adresses ID sont control es 1 255 Uniquement l adresse ID s l...

Page 22: ...dimmer non lin aire Dim 7 200 224 Vitesse dimmer non lin aire Dim 8 225 255 Vitesse dimmer non lin aire Dim 9 AR3d CHANNEL VALUE FUNCTION 1 0 255 DIMMER GENERAL 2 0 255 ROUGE 3 0 255 VERT 4 0 255 BLEU...

Page 23: ...ne doivent pr senter aucun dommage ni signes d usure L installateur doit respecter toutes les consignes de s curit Nous recommandons un nettoyage fr quent de l appareil Utilisez un chiffon humide non...

Page 24: ...n 1 Dur e de vie 50000 hours Norme IP IP 65 Utilisation Int rieure ext rieure Alimentation AC 100 240V 50 60Hz Puissance 300W NOTE IMPORTANTE Les produits lectriques ne doivent pas tre mis au rebut av...

Reviews: