DMX mode address set   

Power on, the screen shows “0—9”, the data is the DMX random address. When there is no DMX in, the light 
would be blackout.   
5 DMX channels for each light, (R.G.B, RGB Dimmer, strobe), Fox example, address 001 occupies the channel 
1, 2, 3,4and 5. Address 508occupies the channel 508,509, 510,511 and 512. 

   

 
 
 
 
 
 
 

Note: after finished adjusting, leave the key alone for 10 second to exit the programming, the digital 

display stop flashing and memorize the selected parameters. 

 

Master-slave  

a)  choose anyone light as the master unit 
b)  The Master is the light which is choose “P**”, others which choose “SLA” are the slaves.   
Change function of the master light, then all lights will work synchronously. 
 

DMX CHANNEL TABLE 

 

DMX channel 

DMX Value 

Detailed functional 

0 – 255 

Red dimmer ( from 0 to 100% ) 

0 – 255 

Green dimmer ( from 0 to 100% ) 

0 – 255 

Blue dimmer ( from 0 to 100% ) 

0 – 255 

RGB dimmer ( from 0 to 100% ) 

0 - 255 

Strobe ( from slow to fast ) 

 

The following points have to be considered during the inspection: 

All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded. 
There must not be any deformations on the housing, glass pane, fixations and installation spots. 
The electric power supply cables must not show any damage, material fatigue or sediments. Further instructions 
depending on the installation spot and usage have to be adhered to by a skilled installer and any safety problems 
have to be removed. 
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or solvents. 

CAUTION

: Disconnect from mains before starting maintenance operation! 

 

Cleaning and Using Frequency of Product 

Please make sure that the light is power off before dismantling or maintaining, it’s very important to keep the light 
clean. Frequent cleaning will ensure maximum brightness output, but also prolong the life time. It’s suggested to use 
the high quality, professional glass detergent and soft cloth to clean the light. It’s not allowed to use alcohol or 
chemical solvent. The inner part of the light should be cleaned by vacuum cleaner at least once a year. 
When the light doesn’t work, please check if the fuse is burnt out or not. If it is, the same fuse should be replaced, 
find out the faulty and restart the light. But please note the repair must be handled by professional. 

Summary of Contents for BAR LED 412

Page 1: ...Copyright LOTRONIC 2012 BAR LED 412 Page 1 L LE ED D W WA AL LL L W WA AS SH HE ER R B BA AR RR RE E L LE ED D BAR LED 412 GB INSTRUCTION MANUAL F MANUEL D UTILISATION...

Page 2: ...tric shock when touching live wired 2 Never look directly into the light source as sensitive persons may suffer an epileptic shock 3 Please be aware that damages caused by manual modifications to the...

Page 3: ...independent switch so that you can turn on or turn off the light randomly Note the ground wire yellow green double color wire must be safely connected the electrical installation must be in accordance...

Page 4: ...ou could set different function running by UP key the third seven segment digital shows current brightness or speed value of the function adjust the value by UP key For detailed please find the below...

Page 5: ...have to be tightly connected and must not be corroded There must not be any deformations on the housing glass pane fixations and installation spots The electric power supply cables must not show any...

Page 6: ...ve DMX LED power 12 x 3W RGB LEDs 3 in 1 Project distance 20m Life time led 50000 hours IP norm IP 64 Working environment indoor Voltage AC 100 256V Power 36W Dimensions 500 x 75 x 68mm N W 3 5kg Elec...

Page 7: ...orsqu il n est pas utilis ou avant de le nettoyer Ne tirez que sur la fiche jamais sur le cordon Lorsque le cordon d alimentation ou un coupleur d appareil est utilis comme dispositif de d connexion c...

Page 8: ...rvu qu il y ait suffisamment d espace pour assurer une ventilation suffisante Lorsque vous installez l appareil choisissez un emplacement qui permet d acc der facilement l appareil afin d effectuer l...

Page 9: ...es 2 et 3 IN O U T I N O U T O U T IN 1 2 3 D M X I N D M X O U T Note Utilisez du c ble double blindage Le diam tre du conducteur de chaque c ble doit tre d au moins 0 5mm PANNEAU DE CONTROLE 1 Affic...

Page 10: ...lent R glage adresse DMX A l allumage l afficheur indique 0 9 cela correspond l adresse DMX Si auncu signal DMX n est re u l afficheur s teint Il y a 5 canaux DMX par barre led Par exemple Un r glage...

Page 11: ...appareil Utilisez un chiffon humide non pelucheux Ne jamais utiliser d alcool et de solvants ATTENTION D brancher l appareil du secteur avant d effectuer des travaux de maintenance Entretien D branch...

Page 12: ...ur e de vie led 50000 heures Norme IP IP 64 Environnement de fonctionnement int rieure Alimentation AC 100 256V Consommation 36W Dimensions 500 x 75 x 68mm Poids 3 5kg NOTE IMPORTANTE Les produits lec...

Reviews: