Safety Instructions

 

Please read these instructions carefully, they include important information about the installation, usage and 
maintenance of this product. 
• Please keep this User Guide for future reference. If you sell the unit to another user, be sure that they also 
receive this instruction booklet. 
• Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to 
is not higher than that stated on the decal or rear panel of the fixture. 
• This product is intended for indoor use only! 
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 
• Always disconnect from power source before servicing. 
• Maximum ambient temperature (Ta) is 104° F (40°C).  Do not operate the fixture at temperatures higher than 
this. 
• In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by 
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the same type of spare parts. 
• Make sure the power cord is never crimped or damaged. 
• Never disconnect the power cord by pulling or tugging on the cord. 
DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the 
disconnect device shall remain readily operable. 

 
Fixture Linking

 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run 
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of 
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can 
support. 

Important

: Fixtures on a serial/data link must be daisy chained in one single line.  Maximum recommended serial 

data link distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 
fixtures 

 
CABLE CONNECTORS 

Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 
 

DMX connector configuration 
 
 
 

 
 
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to 
connect a DMX signal terminator. 
 

CAUTION 

Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a 
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity and 
to make sure the pins are not grounded or shorted to the shield or each other. 

 

INPUT 

 

COMMON 
DMX + 
 DMX- 

Resistance 120 ohm  
1/ 4w between pin 2 
(DMX-) and pin 3 
(DMX+) of the last 
fixture. 
 

GB 

Summary of Contents for 16-2715

Page 1: ...PIXEL STRIP CONTROLLER PIXSTRIP C 16 2715 USER MANUAL MANUEL D UTILISATION BEDIENUNGSANLEITUNG HANDLEIDING Lotronic SA Avenue Z nobe Gramme 9 1480 Saintes Belgium...

Page 2: ...wer cord by pulling or tugging on the cord DISCONNECT DEVICE Where the MAINS plug or an appliance coupler is used as the disconnect device the disconnect device shall remain readily operable Fixture L...

Page 3: ...al coming from the DMX controller DMX output connect to the DMX receiving device Don t connect more than 31 units between the DMX output of the controller and the DMX distributor Don t connect more th...

Page 4: ...de d connexion ce dispositif doit rester facilement accessible Si un interrupteur omnipolaire est utilis comme dispositif de d connexion l emplacement sur l appareil et la fonction de l interrupteur...

Page 5: ...ensions 80 x 30 x 105mm NOTE IMPORTANTE Les produits lectriques ne doivent pas tre mis au rebut avec les ordures m nag res Veuillez les faire recycler l o il existe des centres pour cela Consultez les...

Page 6: ...e muss spezielles Datenkabel verwendet werden Sie k nnen solche DMX Kabel direkt im Fachhandel erwerben oder selbst ein Kabel fertigen Wenn Sie Ihr Kabel selbst herstellen m chten benutzen Sie bitte D...

Page 7: ...t alvorens u het toestel onderhoud Gebruik het toestel niet in ruimtes met een temperatuur van meer dan 40 C In geval van een ernstig probleem stop het toestel direct Verzoek nooit het toestel zelfs t...

Page 8: ...en twee uitgangen die elektrisch zijn ge soleerd E n DMX connector 3 pin is voor 4 enkele kanalen Elke DMX uitgang heeft een onafhankelijke driver en DATA DATA LED indicator DMX ingang Om het signaal...

Page 9: ...ese de que le cable de corriente nunca est da ado o pellizcado Jam s desenchufe el equipo tirando del cable h galo desde la propia clavija y con cuidado No exponga los ojos a la fuente luminosa Cu ndo...

Page 10: ...Cada salida DMX cuenta con un driver independiente y de un ndicador DATA DATA de LED Entrada DMX Conecte la se al que proceda de un controlador DMX Salida DMX A conectar en la entrada DMX de un equipo...

Reviews: