EN
7
www.afx-light.com
•
Press UP or DOWN to adjust the time value of duration (3s - 250S)
•
Press UP or DOWN to adjust the time value of the Interval (5s - 250s)
• Press ENTER to start timing fogging
• Press again ENTER to stop time-controlled fogging.
•
Please note that the machine will stop automatically after a delay of 30 seconds to
clear the tubing of remaining liquid.
•
After cleaning, it goes back into standby status.
OTHER OPERATION TIPS
• Under
or
press MENU to check and set numbers:
•
or
: built-in timer on/off
•
Built-in timer, single fogging duration 3s-250s
•
Built-in timer, interval fogging time 5x-250s
•
DMX address setting 1-512 (press UP and DOWN to set)
REMOTE CONTROL OPERATION
For best result, use VT-1 puff volume adjustable controller.
1. Firmly attach the remote control to socket (Figure1-K) on the back of the unit
2. P.xxx: Displays the previous picture, fogging controlled by display stops working, puff volume
controlled by VT-1;
3. Refer to your controller manual for controller operation details (Appendix A );
• VT-1 only controls the puff volume, the Fan is still controlled by the display. Press UP/DOWN on
the panel to adjust Fan, displays F.xxx , 2 seconds without operation, back to P.xxx .
Press MENU to check current Fan value, displays F.xxx , 2 seconds without operation, back to P.xxx.
DMX CONTROLLED OPERATION
• Connect the DMX 512 controller cable to the input socket (Figure 1-I) of the fog machine. Make
sure the signal cable polarity is correct. When DMX socket receives effective DMX signals, the
machine enters automatically into DMX control mode.
• The unit offers 2 DMX channels. Refer to DMX channel chart in Figure 2 to make related settings
• Interchange puff volume P.xxx / Fan volume F.xxx, every 3 seconds
• A.xxx Press MENU to check current DMX address, press UP/DOWN to set DMX address;
• Displays current puff volume is controlled by DMX;
• After 3 seconds without operation, back to interchange of puff volume / Fan volume
• P.xxx Displays current puff volume, controlled by DMX
• F.xxx Displays current fan volume, controlled by DMX
• If desired, connect another faze machine: Plug one end of another signal cable in to the output
socket (Figure 1-J) on the back of the first FAZE700; plug the other end of the signal cable to the
input socket (Figure 1-I) on the back of the second FAZE700. Follow the same procedure to link
more fog machine, if desired; whole link is daisy chain.
• Down. Refer to DMX channel chart in Figure 2 to make related settings. Now start operating
FAZE700 with a DMX console.
PLEASE NOTE
To reduce the possibility that the wind mouth gets humid, the software will detect the wind value
and the fog value, and do proper adjustment. Under display control mode (timing fogging, conti-
nuous fogging and manual fogging) or DMX control mode :