Page 12
SXT Resets
Reset
Directions
Effect
Soft Reset
Hold Extra Cycle and Down
buttons for 25 seconds
This will reset all settings to default
values, but leaves the volume remaining
intact.
Hard Reset
Hold Extra Cycle button while
plugging the unit in
This will reset everything in the system.
This should only be used if a soft reset
does not work.
Plumbing the system in
Section 7: Plumbing Guidelines
Step 7a: Connecting the bypass
The exact fittings on your system
may vary depending on the exact
configuration of your system, but in
general you will have a bypass valve
and yoke, or a single piece bypass
valve with built-in fittings (Img Left).
You will supply the required fittings
to connect from the system to your plumbing, this
will typically consist of threaded adapters that will
connect directly to the bypass/yoke, fittings to tie into
your main line, and the copper/PVC/PEX line to connect between them. Use Teflon tape, pipe
dope, or joint compound as necessary to ensure a proper seal. If soldering, first solder a short
(min 3-inch [7.6-cm]) piece of copper pipe onto the adapters, away from the valve, before
connecting the adapter to the system fittings.
After the adapters are in place the bypass assembly
can be connected to the control head. The system
uses O-rings to provide a water tight seal, and after
checking each O-ring for any obvious damage a small
amount of silicone lubricant or vegetable oil can be
used to help ensure a good seal. The valve handle(s)
should be facing up when connecting it to the system.
Many homeowners install their own water systems with basic plumbing skills; if you
are not comfortable with projects like this, please hire a professional plumber. Make sure
to check local plumbing codes and follow any codes that apply. These instructions offer
basic plumbing tips and can not cover every situation. They are intended as a supplement
and should not replace local plumbing codes or actual plumbing experience.
Before turning your water off and cutting into your plumbing it is recommended to dry
fit all connections to ensure that you have everything you need.
If soldering do not solder direct-
ly to the included connection or
close to the control head.
It is recommended to attach
the adapters to the bypass or yoke
BEFORE connecting to the control
head to avoid damage.
Do not use petroleum based
lubricants like Vaseline on any of
the O-rings.
Do not over tighten the screws
to avoid damage. Damage from
over tightening is not covered
under warranty.