Page 1: ...lingen Telefon 49 0 7135 102 0 Service 49 0 7135 102 211 Telefax 49 0 7135 102 147 E Mail info afriso de Internet www afriso de Read before usage Please consider notes on safety Store for future usage 06 2009 0 854 001 0502 Systronik Article No 22939 E1 Instruction Manual Temperature Measuring Device S2600 ...

Page 2: ... accessories 5 2 7 Liability information 5 3 Product description 5 3 1 Scope of delivery 5 3 2 Properties and functions 5 4 Technical Data 6 4 1 Approvals tests and conformities 7 5 Transportation and storage 7 6 Operation 9 6 1 Measuring mode 10 6 2 Display light 13 6 3 Device shut down 13 7 Maintenance 13 7 1 Maintenance intervals 13 7 2 Maintenance activities 14 8 Troubleshooting 14 9 Disposal ...

Page 3: ...d the danger are shown here There are three different levels of warnings Warning Meaning DANGER Imminent danger Failure to observe the information will result in death or serious injuries WARNING Possible imminent danger Failure to observe the information may result in death or serious injuries ATTENTION Dangerous situation Non observance may lead to light or medium inju ries or physical damage 1 ...

Page 4: ...e being commissioned This product is only to be used in immaculate state in consid eration with the user manual the usual regulations and guide lines as well as the valid safety directions and accident preven tion regulations External environmental conditions may impede the functioning of the product Product to be protected from shocks Product to be used only in indoor areas Product to be protecte...

Page 5: ...amages incurred by the user by third parties through the use of the device in particular through the incorrect use of the device through misuse or malfunction of the connection and through malfunctions in the device or in connected devices Neither the manufacturer nor the distributing company assume liability for the misuse of the device The manufacturer assumes no liability for printing errors 3 ...

Page 6: ...ment 0 C to 45 C 32 F to 113 F Storage 20 C to 50 C 4 F to 122 F Power supply Nominal voltage Through mains adaptor USB Electric safety Protection class IP 40 EN 60529 Electromagnetic compatibility EMC Transient emissions EN 55011 VDE 0875 11 Interference resistance EN 61000 VDE 0847 4 2 ESD EN 61000 4 2 Table 2 Product specifications Basis Version S2600 12K TM 7 S2600 12KD TMD 7 Measurement range...

Page 7: ...nnector 2x Thermo connector 4 1 Approvals tests and conformities The temperature measuring device S2600 is approved according to 1 BImSchV and EN 50379 2 and TÜV certified It is in accordance with the EMV directive 2004 108 EG 5 Transportation and storage ATTENTION Device may be damaged through inappropriate transportation Do not throw device or drop it ATTENTION Device may be damaged through inap...

Page 8: ...Transportation and storage 8 S2600 ...

Page 9: ... Segment test All available display segments are shown for approx 2 seconds For control purposes the display of all segments can be pro longed through holding the ON OFF key 4 Serial No and Firmware Version This screen displays the serial no e g 123 of the device as well as the firmware version e g V1 0 12 ...

Page 10: ...s is additionally equipped with the function to display the dif ferential temperature Functions Min Max and The functions Min and Max allow a switching of the display be tween the minimum maximum and currently measured value With each pressing of the Program Selection key the display changes to one of the available readings minimum maximum cur rent reading If the minimum or maximum value is displa...

Page 11: ...Operation S2600 11 The Min and Max values can be reset with the Reset key Shut down of the device also resets the values S2600 12K TM 7 S2600 12K TMD 7 S2600 12KD TM 7 S2600 12KD TMD 7 ...

Page 12: ...tion 12 S2600 Unit conversion C to F and F to C Through pressing the Menu key the temperature display can be switched to Celsius or Fahrenheit S2600 12K TM 7 S2600 12K TMD 7 S2600 12KD TM 7 S2600 12KD TMD 7 ...

Page 13: ...isplay light The display light can be switched on or off with the ON OFF key Thereby pressing the key shortly is sufficient 6 3 Device shut down Press the ON OFF key for approx 2 seconds A time dependent auto shut down function is currently not imple mented 7 Maintenance 7 1 Maintenance intervals Table 3 Maintenance intervals When Activity If required Batteries replacement Device cleaning ...

Page 14: ...tally compatible disposal 8 Troubleshooting Repair work may only be carried out by qualified specially trained personnel Table 4 Troubleshooting Problem Possible reason Error repair Device doesn t switch on Empty batteries Replace batteries No temperature displayed Temperature sen sor defective Send device to manufacturer Other errors Return the device to the manufacturer refer to chap ter Fehler ...

Page 15: ...nual may only be reprinted translated copied in part or in whole with the prior written consent of the manufacturer We reserve the right to modify any specifications or alter any illustra tions in this manual without prior notice 13 Customer satisfaction Customer satisfaction is our prime objective Please get in touch with us if you have any questions suggestions or problems regarding your product...