EN 6
AFPUMPS S.r.l.
E-mail: [email protected]
h p:// www.afpumps.com
Tel. +39 0429 77 82 95 - Fax +39 0429 76 30 49
THREEPHASE electrical connec on: direct start Y
M
Y
(400 Volts)
Thermal probe T1 = Cable n° 4 Black = White or White/Black
Thermal proble T2 = Cable n° 5 Black = White or White/Grey
Umidity probe = Cable n° 6 Black = Green or White/Brown
KIT M/S = OPTIONAL
Line 1 U1 = Cable n° 1 Black = Blue
Line 2 V1 = Cable n° 2 Black = Brown
Line 3 W1 = Cable n° 3 Black = Black
Yellow/Green
THREEPHASE electrical connec on: start Y/Δ
Thermal probe T1 = Cable n° 7 Black = White or White/Black
Thermal probe T2 = Cable n° 8 Black = White or White/Grey
Umidity probe S = Cable n° 9 Black = Green or White/Brown
KIT M/S = OPTIONAL
Line 1 U1 = Cable n° 1 Black = Blu
Line 2 V1 = Cable n° 2 Black = Brown
Line 3 W1 = Cable n° 3 Black = Black
Line 1 W2 = Cable n° 4 Black = Black
Line 2 U2 = Cable n° 5 Black = Blue
Line 3 V2 = Cable n° 6 Black = Brown
Yellow/Green
M
Y/Δ
(400/690 Volts)
START
Before installing the mixer, you must make sure that, with the machine not connected
to the power supply line, the rotor rotates freely: for this purpose you can operate on
the propeller. It is also necessary to check that the direc on of rota on is correct, ie
clockwise viewed from the front of the machine.
To do this, before installa on, suspend the mixer and start the engine for a few
seconds
(staryt and stop)
: if the direc on of rota on is correct, the mixer undergoes
a counterclockwise kickback when viewed from the front. When carrying out this test, make sure
that the machine is at a safe distance from people, animals or things.
To change the direc on of rota on, swap two phases of the power supply line together.