Troubleshooting 63
4510012 - REV F – 220621
Troubleshooting
Below are some common problems that may be encountered during steam heat shrinking. If
other issues occur that are not covered in this section, call your authorized AFM distributor for
assistance.
WARNING:
Live steam and burn hazard. Use caution. Failure to follow this
directive can result in serious injury.
WARNING:
Always wear proper safety equipment, including Heat-resistant Work
Gloves and Safety Glasses/Goggles when operating or maintaining the GEN-S.
ATTENTION:
Do not attempt to perform troubleshooting beyond what is described
in this User Guide. Failure to follow this directive can result in injury, damage the
equipment, and will void the warranty. If in doubt, contact your AFM distributor.
Problem
Possible Cause
Solution
Boiler does not fill.
No water supply.
Ensure that the Water Valve to the
Boiler is in the Open position.
Sight Glass Valves are closed,
resulting in the Sight Glass not
properly displaying the amount
of water in Boiler.
Ensure that both Sight Glass
Valves are open.
Open or leaky Drip Valve below
Sight Glass, resulting in the
Sight Glass not properly
displaying the amount of water
in Boiler.
Check for water below the Drip
Valve. If any water, ensure that
Drip Valve is closed. If problem
continues, contact AFM.
Probes are improperly
connected.
Check that each Probe is
connected to the correct wire (see
Leak elsewhere in the system.
Contact AFM.
Water Pump on the Boiler has
failed.
Replace the Water Pump (Part
Number 4502781).
Summary of Contents for STC-WSN300-2M
Page 1: ...WSN GEN S Steam Heat Shrink Tunnel User Guide ...
Page 2: ...2 Abbreviations 4510012 REV F 220621 ...
Page 8: ...8 Abbreviations 4510012 REV F 220621 ...
Page 66: ...66 Troubleshooting 4510012 REV F 220621 ...
Page 67: ...Electrical Schematics 67 4510012 REV F 220621 Electrical Schematics Complete System WSN GEN S ...
Page 68: ...68 Electrical Schematics 4510012 REV F 220621 Boiler ...
Page 72: ...72 Parts List 4510012 REV F 220621 Exploded Diagrams Stand Drawing Number YS130EX2 01 ...
Page 74: ...74 Parts List 4510012 REV F 220621 Tunnel Drawing Number YS130EX2 02 ...
Page 78: ...78 Parts List 4510012 REV F 220621 Boiler ...
Page 79: ...Parts List 79 4510012 REV F 220621 Inside Boiler Electrical Cabinet ...