52 Maintenance
4510012 - REV F – 220621
Maintenance Schedule
Adherence to the maintenance schedule below will extend the life of the GEN-S, ensure the
best performance, and reduce the likelihood of injury.
Frequency
Maintenance Task
Every hour during operation
Visually check the water level in the Sight Glass.
Check for leaks from the Sight Glass. If leaks are found, tighten
the Sight Glass fixture nuts or replace the Sight Glass gaskets
Every 4 hours during first week
Perform blowdown procedure (see “Blowdown Procedure” on
).
Daily at end of workday
Perform blowdown procedure (see “Blowdown Procedure” on
).
Every 2 weeks
Clean or replace the Strainer (see “Cleaning or Replacing the
).
Every 3 months
Perform manual cleanout (see “Manual Cleanout” on page
).
Check and clean the Probes (see “Checking and Cleaning the
).