AFL Hyperscale 6RU Installation Manual Download Page 10

10

© AFL Hyperscale. All rights reserved

Series

Cable Installation 

Close the back panel and re-fit the side cover 
using a screwdriver.

19

Remove the knockout section from the side 
cover using pliers.

18

Route the incoming fiber 

(BLUE)

 as per the image above - store up to 1.5m of 144f ribbon fiber. Factory-installed 

ribbon pigtail fiber shown in 

GREEN

.

 Splice according to the splice schedule.

17

Fiber Retainer Clips

Fiber Retainer Clips

Summary of Contents for 6RU

Page 1: ...Installation Guide 6RU Splice and Patch Panel Series ...

Page 2: ...for an eye examination immediately General Precautions Personnel must be thoroughly familiarized with all applicable Occupational Health and Safety OH S regulations local regulations and your company safety practices and policies Warning To reduce the chance of accidental injury Before work begins all personnel must be thoroughly familiar with the operation of all equipment and procedures to be us...

Page 3: ...3 U Series 6RU Splice and Patch Panel AFL Hyperscale All rights reserved Series Component Overview 01 02 04 05 03 ...

Page 4: ...72 08 Ø30mm Conduit 1 09 24f LC Ribbon Pigtail 36 01 U Series 6RU Splice and Patch Panel 04 Cable Clamp Cross Head Screwdriver 07 12f Ribbon Splice Protector Pliers 02 U Series Patch Adapter Plate 05 Pivot Splice Tray Stack Socket Wrench 08 Ø30mm Conduit 03 Front Door 06 M6 Cage Nuts Screws 09 24f LC Ribbon Pigtail What You Will Need Related Products 250 μm WTC with SWR MicroCable Assemblies 2mm T...

Page 5: ... Series Panel Mounting Remove the cable clamp 04 using a screwdriver 4 Remove the shipping bracket side fixing bolts using a socket wrench 3 Remove the panel 01 from the packing crate 2 Remove the four shipping bracket fixing bolts using a socket wrench and a screwdriver 1 ...

Page 6: ...ack and tighten the cage nut screws 06 using a screwdriver 7 Partially tighten the cage nut screws 06 in the positions shown left and right hand side using a screwdriver 6 Panel Mounting Insert the cage nuts 06 in positions shown above on both the left and right hand sides of the rack 5 2U 6U 2U Slotted bracket for ease of installation ...

Page 7: ...7 U Series 6RU Splice and Patch Panel AFL Hyperscale All rights reserved Series Panel Mounting Re attach the cable clamp 04 using a screwdriver 10 Mount the door 03 onto the panel 01 9 ...

Page 8: ...ble sub units fiber bundles 14 Strip the cable jacket in accordance with the cable manufacturer s guidelines 13 Clamp the cable and tighten using a socket wrench allowing a min of 2m for jacket stripping 12 Open the rear panel and remove the bottom side panel with a screwdriver 11 Approx 2m 50mm ...

Page 9: ...d Patch Panel AFL Hyperscale All rights reserved Series Cable Installation Remove the splice tray cover 16 Feed the conduit 08 into the panel and clip it into the conduit clamp 15 Clip Splice Schedule Latch Tab Latch Tab Clip ...

Page 10: ...ing a screwdriver 19 Remove the knockout section from the side cover using pliers 18 Route the incoming fiber BLUE as per the image above store up to 1 5m of 144f ribbon fiber Factory installed ribbon pigtail fiber shown in GREEN Splice according to the splice schedule 17 Fiber Retainer Clips Fiber Retainer Clips ...

Page 11: ...11 U Series 6RU Splice and Patch Panel AFL Hyperscale All rights reserved Series Notes ...

Page 12: ...Thank you for choosing AFL Hyperscale AFLHS6RUSPP270820 www aflhyperscale com AFL Hyperscale reserves the right to make changes in this Installation Guide at any time without notice ...