Afikim Afiflo 2000 Installation Manual Download Page 9

Installation procedures for ICAR certified meters 

Afiflo 2000 

Version July 2018 

Installation manula for Afiflo 2000 mik meter - Page 9 of 33. 

 

4.1

 

The Start-up Sequence 

Afiflo 2000 milk meters are usually installed so that the display panels turn on when power 
to the milking parlor is switched on. 

During installation, each milking point is assigned an identification number. 

Immediately after power to the milk meters is switched on, the following occurs: 

a.

 

For several seconds, the milking point’s identification number—

Id##

 — appears in 

the milk yield field. For example, for milk meter number one, 

Id01

 appears. The 

identification number is replaced with 00.0 indicating the beginning of normal start-
up or 

00.0L

 if set to work in Pounds. 

b.

 

In the cow number field, two zeros flash. 

The Afiflo 2000 milk meter starts-up in Cleaning Mode. The red indicator of the Cleaning 
Mode key indicates that the milk meter is in Cleaning Mode. 

Press 

on each meter to alternate from Cleaning Mode to Milking Mode. 

When the red LED goes off, the milk meter is in Milking Mode. 

4.2

 

The Primary Fields 

Once a cow arrives at the milking point and 

before

 the start of milking, The control panel 

receives important information from the computer. This information is displayed in two of 
the four fields pictured below; the milk yield of the present milking is shown in the third field. 
This chapter describes these three fields. The fourth field, the pulsation and strip field, is 
explained in a following chapter. 

Two LCD (liquid crystal display) fields display milk expectations, messages, and a choice of 
DIM (days in milk), fertility or, in the future, feed data. The LCD fields are explained in a 
following chapter. 

 

4.3

 

Cow Number Field 

Upon entering the milking point, the cow is identified. Following identification, the cow's 
number appears in the cow number field. If the cow is not identified, two zeroes flash. A cow 
might not be identified if: 

a.

 

The tag has fallen off. 

b.

 

Either the tag or the receiver is faulty. 

Summary of Contents for Afiflo 2000

Page 1: ...ICAR Guidelines for installation of the milk meters Afiflo 2000 Version July 2018...

Page 2: ...ys 11 4 5 Parlor alarms 13 5 Chapter 3 Monitoring data and sending messages 14 5 1 Sending messages 17 6 Chapter 4 Special features and operations 19 6 1 Controlling entry and exit gates 20 6 2 Data s...

Page 3: ...spect is multi faceted The communication a Enables milkers while still in the parlor to monitor information about the cows Based upon upto date information milkers and herd managers can make immediate...

Page 4: ...operational aspects of Afiflo 2000 are automatic However the communication aspect is multi faceted The communication a Enables milkers while still in the parlor to monitor information about the cows B...

Page 5: ...er Page 5 of 33 A brief description of these components follows 3 1 The Milk Meter Body The Afiflo 2000 milk meter body needs little space in the parlor and is easy to maintain Electrodes in the body...

Page 6: ...k meter control panel is essentially a computer terminal Milking operations are controlled from it and all relevant cow information can be viewed in the display windows It is thin and compact Below is...

Page 7: ...rinted circuit board PCB of the AfiFlo 2000 milk meter is contained in the controller One controller for each meter is mounted overhead in the parlor above its respective control panel and body All co...

Page 8: ...f 33 4 Chapter 2 Operation Operation of the Afiflo 2000 milk meter involves three steps a Monitoring primary displays b Use of cluster control keys c Responding to alerts This chapter explains the sta...

Page 9: ...the milk meter is in Cleaning Mode Press on each meter to alternate from Cleaning Mode to Milking Mode When the red LED goes off the milk meter is in Milking Mode 4 2 The Primary Fields Once a cow ar...

Page 10: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 10 of 33 c The ID tag is not registered in the database...

Page 11: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 11 of 33 4 4 The operation keys...

Page 12: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 12 of 33...

Page 13: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 13 of 33 4 5 Parlor alarms...

Page 14: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 14 of 33 5 Chapter 3 Monitoring data and sending messages...

Page 15: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 15 of 33...

Page 16: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 16 of 33...

Page 17: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 17 of 33 5 1 Sending messages...

Page 18: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 18 of 33...

Page 19: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 19 of 33 6 Chapter 4 Special features and operations...

Page 20: ...procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 20 of 33 6 1 Controlling entry and exit gates 6 2 Data storage 6 3 Pulsation and...

Page 21: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 21 of 33 7 Chapter 5 Cleaning route 7 1 Recommendations...

Page 22: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 22 of 33 7 2 General instructions...

Page 23: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 23 of 33 7 3 Cleaning cycle...

Page 24: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 24 of 33 7 4 Operation in cleaning mode...

Page 25: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 25 of 33 8 Chapter 6 Milk meter body and fat sampler...

Page 26: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 26 of 33...

Page 27: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 27 of 33 8 1 Silicone and rubber component replacement...

Page 28: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 28 of 33 8 2 The fat sampler...

Page 29: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 29 of 33 9 Chapter 7 Troubleshooting...

Page 30: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 30 of 33 10 Appendix Milk meter software version 19 01...

Page 31: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 31 of 33 10 1 Toggling cluster level...

Page 32: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 32 of 33...

Page 33: ...Installation procedures for ICAR certified meters Afiflo 2000 Version July 2018 Installation manula for Afiflo 2000 mik meter Page 33 of 33...

Reviews: