5.  To start milking, press the              key.  This starts the vacuum and 

releases the cluster.   
If a code is assigned to the cow: 

a.  Make the necessary preparations as required by the code. 

b.  Press                                   (twice rapidly) to start milking.  

Stimulation 

The default setting is without stimulation pulsation: 

• 

To activate pulsation, press                                     

(twice rapidly) to start milking with stimulation. 

• 

If a code is assigned to the cow, 

and

 if you want to activate stimulation:

a.  Make the necessary preparations as required by the code. 

b.  Press                                                          (three times rapidly)   

to start milking with stimulation.   

6.  Attach the cluster. 

(Very slow cows are milked with ACR deactivated.  To 
deactivate the ACR press the ACR Cancel key  (              ). 
 
The red LED glows, indicating that ACR is deactivated.  When 
  
the cow has finished milking, press the               key to shut off 
the vacuum and retract the cluster.) 

7.  Repeat steps 5 and 6 for each cow. 

While milking is in process, the milk yield appears in the display.  In addition, 
the milker can view the conductivity and additional cow information, as 
described in the following section.   

8. 

Cluster removal occurs when the milk flow rate drops below a predefined 

level.  The ACR function shuts off the vacuum and retracts the cluster. 

9. 

When all of the cows in the row are finished milking, release the 

cows and repeat the process starting from step 4.  The display is reset 
  
when               is pressed. 

 

WARNINGS: 

1.  Automatic cluster removal does not take place in this mode.  

Therefore, preventing over-milking—that is, manually 
stopping the milking—is the full responsibility of the milker. 

2. The 

Afi-lite

 milk meter does not automatically reset to ACR 

mode.  To restore ACR for the next cow, press the Cancel 
ACR key.  The red LED in the key turns off, indicating that 
ACR is activated. 

this page updated: July 27, 2003 

Summary of Contents for Afi-lite Plus

Page 1: ...lite Plus Milk Meter Product number 4098999 User Manual http February 27 2003 Kibbutz Afikim 15148 ISRAEL 972 4 675 4811 972 4 675 1862 market afimilk co il www afimilk co il This manual P N 9040310...

Page 2: ...Afi lite User Manual P N 9040310 b...

Page 3: ...ine 19 Warnings 19 Recommendations 19 General Instructions 20 Cleaning Cycle 20 Detergent Wash 21 Acid Wash 22 Operation in Cleaning Mode 22 Chapter 4 Milk Meter Body and Fat Sampler 23 The Milk Meter...

Page 4: ...Afi lite User Manual P N 9040310 d...

Page 5: ...ment display when starting up has been corrected June 17 2003 6 one sheet Stimulation activation instructions are added July 27 2003 9 10 one sheet When assigned to an animal ALL milking codes 1 8 dea...

Page 6: ...Afi lite User Manual P N 9040310 f...

Page 7: ...e following tasks during milking Measures the amount of milk produced Measures conductivity of the milk Controls Automatic Cluster Removal ACR Displays cow information Alerts milkers to health and mil...

Page 8: ...Afi lite User Manual P N 9040310 2...

Page 9: ...February 27 2003 Afi lite User Manual 3 The Afi lite milk meter control box Chapter 2 The Milk Meter Control Box This chapter describes operation of the Afi lite milk meter control box...

Page 10: ...ou to attach the cluster to the jetter while other cows are still being milked The Cancel ACR key Afi lite will detach the cluster automatically when the milk flow rate drops to a predefined level Man...

Page 11: ...of each Afi lite milk meter This cancels the cleaning mode and the milk meter enters into milking mode 3 Press the key of each milk meter This shuts off the vacuum and retracts the cluster 4 Bring th...

Page 12: ...press the key to shut off the vacuum and retract the cluster 7 Repeat steps 5 and 6 for each cow While milking is in process the milk yield appears in the display In addition the milker can view the...

Page 13: ...letter For example cow number A123 is displayed as 123 Group Number Press and simultaneously to see the group number of the cow identified at the milking point Milking Point Stall Number Press and si...

Page 14: ...taneously to see the number of days that have passed since the cow calved Days after Insemination Press and simultaneously to see the number of days that have passed since the cow was last inseminated...

Page 15: ...h the cow number For example if cow 1305 has just calved Codes 1 through 8 can be assigned to and canceled from cows from Afi lite milk meters in the parlor Assigning codes is explained in the followi...

Page 16: ...se a big cluster on a cow with large udders Code 7 is also displayed after cluster removal Therefore this code may be appropriate for situations where milk needs to be diverted such as with cows under...

Page 17: ...used to designate an antibiotic cow 8 Colostrum cow To see a code during milking press and hold The code alternates with the cow number Alerts Mastitis alert Premature cluster removal Milk yield flas...

Page 18: ...s are predetermined and they are used to assign a code cancel a code or to send a letter Predetermined Messages As detailed in the table below certain messages specific numbers are predetermined for s...

Page 19: ...322 The milk meter display returns to its previous reading after the message is entered Example C A message can be sent to delete cancel a code from a cow For example to cancel code 2 from cow 1405 At...

Page 20: ...Afi lite User Manual P N 9040310 14...

Page 21: ...he original ID number The identification number of each milk meter is displayed on its control panel with four digits It begins with the letters followed by two numbers For example is the identificati...

Page 22: ...e of milk from the cow decreases the milk meter body is emptied at greater intervals When the milk meter body is not emptied within the time specified in the cluster is removed Milk flow rate is calcu...

Page 23: ...ss simultaneously appears for a few seconds Then 1st parameter in the family appears While appears press respective short cut key For press short cut For press short cut For wait a few seconds until i...

Page 24: ...Afi lite User Manual P N 9040310 18...

Page 25: ...h chemical detergents Prevent any contact with active detergents and acids in the same container Avoid all contact of pesticide materials with the exterior of AfiFlo milk meter bodies and control pane...

Page 26: ...d to the jetters During every stage of cleaning check that there is sufficient water to flood the interior chamber of the milk meter bodies The volume of each milk meter body is 500cc The amount of wa...

Page 27: ...s may be baked onto the surfaces 2 Circulate the water in a closed circuit CIP with detergent Use a basic detergent additive pH 13 and hot water Entry water 70 C 158 F or hotter Returning water 55 C 1...

Page 28: ...s thereby preventing excessive load on the power supply The schedule creates a delay of 100 msec between stalls and is set according to milking point numbers Every seventh milking point has the same d...

Page 29: ...te User Manual 23 Chapter 4 Milk Meter Body and Fat Sampler This chapter contains information about The basic structure and components of the AfiFlo milk meter body Silicone and rubber component repla...

Page 30: ...Meter Body Structure and Components Valve Milk inlet Electrode Electrode Electrode Silicon Diaphragm Milk Outlet Upper Cover and Milk Inlet Upper Gasket Mid Section Lower Cover and Milk Outlet Lower G...

Page 31: ...ilk portions may vary from 180 250 cc When the solenoid valve is energized vacuum from the solenoid line causes the silicon diaphragm to pull the valve down This releases a portion of the milk Dependi...

Page 32: ...10 M cable Replace annually 4 AfiFlo body valve gasket 4098072 4098072 4098072 5 AfiFlo body milk valve 4098070 4098070 4098070 6 AfiFlo body lower cover 4098040 4098040 4098040 Replace annually 7 Af...

Page 33: ...February 27 2003 Afi lite User Manual 27...

Page 34: ...ilk line Fat Sampler Operation The fat sampler is made up of a sampling bottle and a sampler head Milk is sampled each time the meter body is emptied As the milk flows out of the milk meter body a sma...

Page 35: ...uctivity and to identify the problem To continue milking from the previous milk measurement 1 Press 2 Reattach the cluster Error Alerts Error alerts flash in the display panel of the milk meter They a...

Page 36: ...Probable cause Solution Afi lite control box display is not illuminated Power supply cable is not properly connected to the Afi Lite control panel Check and correct When power is turned on Afi lite c...

Page 37: ...uster removal 29 B back flush assembly 25 F fat sampler 25 arrow on head of 28 mounting 28 M milking point identification number 15 P power supply excess load 22 S single vacuum shut off valve 25 stal...