26 April, 2002
FIRMWARE UPDATE PROCEDURE
5-7
Service
Tables
Preparation on the PC
1. Set the TCP/IP address for your PC (e.g. 133.139.157.010).
NOTE: NOTE:
Do not use the IP address of the printer.
2. Set the Subnet Mask (e.g. 255.255.255.0).
3. Reboot the PC.
Upgrade Procedure
1. Check that the printer front cover is open.
2. Run the Web
browser.
3. Type the printer IP address into the Web browser to run Fiery WebTools.
NOTE:
The printer IP address is the address you have input in the submenu
Eth. IP Address."
4. Click the Web
Downloader button of Fiery WebTool.
5. Click the Print
Connection button, and select the following option:
0: Direct Connection
6. Browse through the source file list, and select the firmware.
7. Click the Send
file button.
8. Wait until the Data In LED blinks.
9. Check that the massages Upgrading System
and Do Not Power Off are displayed.
NOTE:
Do NOT turn the main switch off before
the messages disappear.
10. Wait until the Data In LED goes out. The
printer reboots automatically.
11. Close the front cover when “Close Front Cover” is displayed.
NOTE:
Fiery WebTools does not output any message or indication at the end
of firmware upgrading. Quit Fiery WebTools by clicking the close button
(x) after Ready is displayed.
12. Check the firmware version by printing
Configuration Page
.
13. Return all printer settings that were changed in order to perform the upgrade
back to their original values.
Upgrading System
Do Not Power Off
G082S912.WMF