AFi RT-913D Instruction Manual Download Page 5

 

5

DATA INPUT / OUTPUT CONNECTIONS 

Data input and output connections are made via terminal blocks on the back of the unit. See the 
drawings below for proper orientation of input and output connections. Please note that the far right pin 
on each connection drawing corresponds with the far right pin when looking at the terminal block from 
the back of the unit. 

 

TYPICAL SYSTEM DATA CONNECTIONS 

The RS422 or RS485 four wire interconnection between the RT-913D and the copper device to which it 
is attached is based on industry standard EIA terminology for the transmission of electronic data 
signals. Using this terminology, the driver of an electronic signal is labeled TX or Data Out. 
Correspondingly, the receiver of an electronic signal is labeled RX or Data In. Following this standard, 
the Data Out of the copper device is connected to the Data In of the RT-913D. The plus terminal of the 
copper device is connected to the plus terminal of the RT-913D and the minus is connected to the 
minus. The reverse flow of data from the RT-913D to the copper device follows the same pattern. Not 
all manufactures follow standard EIA terminology. Consult the installation instructions for your copper 
device if you are unsure which two wires are the drive (data out) wires and which two wires are the 
receive (data in) wires.  

 
DATA CONFIGURATION 

NOTE: This unit is shipped in the following default configuration.  
 

Channel 1: RS422 data 
Channel 2: RS485 (4 wire) or Manchester data  
Channel 3: RS232 data  

For other configurations, please refer to the drawing below for changes to the default switch settings. 
These configuration switches are located on the left side of the unit and can be modified without 
opening the unit. 

Refer to FUNCTIONAL DESCRIPTION section for a list of allowable channel 

configurations.

 

 

Summary of Contents for RT-913D

Page 1: ...Copyright 2005 American Fibertek Inc 0825JD Instruction Manual RT 913D Video Transmitter With Bi directional Multi Protocol Data And Remote Diagnostic Interface...

Page 2: ...ion 4 Power Source 4 Power Connection 4 Fiber Connection 4 Video Input Connection 4 Data Input Output Connections 5 Typical System Data Connections 5 Data Configuration 5 RS485 Data Signals 6 Offset B...

Page 3: ...l 3 RS232 data The RT 913D is designed to operate with the MR 913D or RR 913D video receiver with bi directional data over one multimode fiber optic cable The RT 913D multiplexes a single video input...

Page 4: ...o the unit via a four finger backplane connector The RR 913D can be inserted into the subrack or removed from the subrack with power applied to the backplane FIBER CONNECTION The fiber optic connectio...

Page 5: ...a Out of the copper device is connected to the Data In of the RT 913D The plus terminal of the copper device is connected to the plus terminal of the RT 913D and the minus is connected to the minus Th...

Page 6: ...nsmitter devices to go into a high impedance Hi Z state This allows multiple transmitter devices to reside on the same wire pair The software must dictate a protocol that allows only one device to tra...

Page 7: ...LED indicator is provided to monitor the data coming in from the fiber through the RT 913D and out onto the electrical interface The intensity of this indicator will vary with input data patterns howe...

Page 8: ...n Material Authorization RMA number is required to send the products back in case of return All returns must be shipped prepaid This warranty is void if the products have been tampered with This warra...

Reviews: