background image

 

7

MT-746C-SL STATUS INDICATORS 

The MT-746C-SL transmitter provides the following LED status indicators to aid in installation and 
troubleshooting: 

 
DATA TX / RX INDICATORS 

DATA TX and DATA RX indicators are provided to monitor the data and contact closure channels. TX1 
and RX1 correspond with the multi-protocol input/output of data channel 1. TX2 and RX2 correspond 
with the input/output of contact closure channel 2.  

 
DATA TX 

A green LED indicator is provided to monitor the data/contact closure coming in from the electrical 
interface, through the MT-746C-SL, and out onto the fiber. The intensity of this indicator will vary with 
input data patterns, however in typical data applications it will cycle on and off as data is transmitted. 
For contact closure applications, this LED will be on solid when the CONTACT IN terminals are 
connected together. Data/contact closure transmitted status associated with this LED is summarized 
below. 
 

DATA TX LED 

Data Status  

Contact Closure Status  

Green 

Data Flow Present  

Contact In Pins Shorted  

Off 

Data Flow Not Detected 

Contact In Pins Open 

 
DATA RX 

A green LED indicator is provided to monitor the data/contact closure coming in from the fiber, through 
the MT-746C-SL, and out onto the electrical interface. The intensity of this indicator will vary with input 
data patterns, however in typical data applications it will cycle on and off as data is received. For 
contact closure applications, this LED will be on solid when the CONTACT OUT terminals are joined 
together. Data/contact closure received status associated with this LED is summarized below. 
 

DATA RX LED 

Data Status  

Contact Closure Status  

Green 

Data Flow Present  

Contact Out Pins Shorted  

Off 

Data Flow Not Detected 

Contact Out Pins Open 

 
VLI 1 THROUGH VLI 4 

A bi-color LED indicator is provided for each of the four video inputs to the MT-746C-SL. DC power and 
video status associated with each of these LED’s are summarized below. 
 

Video Presence LED 

DC Power Status 

Video Status 

Green 

On  

Proper Input Video Present 

Red 

On 

Input Video Not Detected 

Off 

Off 

Check Power Supply 

 

OLI 

A bi-color LED indicator monitors the optical input power of the data signal that is being received at the 
MT-746C-SL from the MR-746C or the RR-746C. DC power and optical input status associated with 
this LED are summarized below. 
 

Optical Level Indicator 

DC Power Status 

Optical Status 

Green 

On  

Proper Optical Input Power Present 

Red 

On 

Optical Input Not Detected 

Off 

Off 

Check Power Supply 

 

Summary of Contents for MT-746C-SL

Page 1: ...11 02 2012 JPK Instruction Manual MT 746C SL Four Channel Video Transmitter With One Bi Directional Multi Protocol Data Channel And One Bi Directional Contact Closure Channel afi american fibertek ...

Page 2: ...deo Input Connections 4 Data Input Output Connections 4 Typical System Data Connections 5 Contact Closure Input Output Connections 5 Data Configuration Switches 5 Data Termination And Offset Bias Switches 6 RS485 Data Termination And Offset Bias 6 MT 746C SL Status LED Indicators 7 Warranty and Service Information 8 ...

Page 3: ...NATION BIAS section for changes to the default switch settings The MT 746C SL multiplexes four video input signals along with one data signal and one contact closure signal into a high speed serial data stream This serial data stream modulates a laser at 1310nm wavelength The MT 746C SL also detects and demultiplexes a return optical serial data stream containing one data signal and one contact cl...

Page 4: ...n appropriate 75 baseband video source such as a camera or a video recorder output For optimum performance the video cables should be the shortest length of coax practical DATA INPUT OUTPUT CONNECTIONS Data input and output connections are made via the terminal block labeled DATA 1 on the left side of the unit See the drawings below for proper orientation of input and output connections Please not...

Page 5: ...out wires and which two wires are the receive data in wires Please note that Data In on the MT 746C SL becomes Data Out on the MR 746C or the RR 746C after going across the fiber The reverse flow follows the same orientation CONTACT CLOSURE INPUT OUTPUT CONNECTIONS Contact Closure input and output connections are made via the terminal block labeled DATA 2 on the left side of the unit See the drawi...

Page 6: ...on of the original RS422 protocol RS485 differs from RS422 in the ability of the transmitter devices to go into a high impedance Hi Z state This allows multiple transmitter devices to reside on the same wire pair The software must dictate a protocol that allows only one device to transmit at any one time to prevent data crashes In many cases the system head end controller will continuously poll da...

Page 7: ...he data contact closure coming in from the fiber through the MT 746C SL and out onto the electrical interface The intensity of this indicator will vary with input data patterns however in typical data applications it will cycle on and off as data is received For contact closure applications this LED will be on solid when the CONTACT OUT terminals are joined together Data contact closure received s...

Page 8: ...R THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In any event American Fibertek will not be responsible or liable for contingent consequential or incidental damages No agreement or understanding expressed or implied except as set forth in this warranty...