AFCO AF 976734 Installation & Operation Instructions Download Page 4

Troubleshooting Guide

AF 976734 • Vision Satellite Entryway Foam Sanitizer

Problem

Possible Cause / Solution

Startup

Maintenance

A) Foamer will not draw chemical.
B) Foam surges.
C) Foam output too wet.
D) Foam output too dry.
E) Doesn't come on when switch is turned on.
F) Comes on and runs continuously.
G) Comes on but no water through solenoid.
H) Air or solution backing up into water line.

1, 7, 8, 9, 10
1, 2, 3, 4, 6, 7, 8, 9, 10
2, 3, 4, 6, 7, 8, 9, 10
1, 5
11,12
11
10

13, 14, 15, 16, 17, 19, 20
13, 14, 15, 16, 17, 19, 20
13, 14, 15, 16, 17, 18, 19, 20
17

19
21

Possible Cause / Solution

Startup

Maintenance

1. 

Air pressure too high

Adjust air regulator slowly counterclockwise until output stabilizes.

2. 

Air adjustment too low

Adjust air regulator very slowly clockwise.

3. 

Use of an oiler in the airline will cause poor foam quality

Use only clean, dry air.

4. 

Not enough chemical - metering tip too small

Install larger metering tip.

5. 

No metering tip installed or metering tip too large

Install smaller metering tip.

6. 

Improper chemical

Ensure product is recommended for foaming and/or the
application.

7. 

Chemical tube not immersed in chemical or chemical depleted

Immerse tube or replenish

8. 

Foam hose kinked or hose/plumbing too short or wrong size 

(See REQUIREMENTS on page 1)

9. 

Water pressure too low or water volume too low/inlet piping too
small

Increase water pressure or water volume. (See REQUIREMENTS
on page 1)

10. 

No water to the unit

Ensure that the water supply is not shut off to the unit.

11. 

Timer failed/Controller not set properly or malfunctioned

Replace timer. See Controller manual.

12. 

May have electrical problems

Ensure circuit breaker (5 Amp) has not been tripped.
Have a qualified electrician check electrical connections. 

13. 

Chemical check valve stuck or failed

Clean or replace.

14. 

Chemical strainer or metering tip partially blocked

Clean or replace chemical strainer and/or metering tip.

15. 

Chemical tube stretched out where tube slides over check valve or
pin hole/cut in chemical tube (sucking air in)

Cut off end of tube or replace tube.

16. 

Vacuum leak in chemical pick-up connections

Tighten the connections.

17. 

Air regulator failed allowing too much air or not enough air

Clean or replace.

18. 

Air check valve or air solenoid clogged or failed

Clean or replace.

19. 

Water solenoid clogged or failed

Clean or replace the water solenoid.

20. 

Chemical build-up may have formed in the body, causing poor or no
chemical pick-up

Follow PREVENTIVE MAINTENANCE instructions below, using
hot water or descaling acid. When there is no draw at all,
carefully remove fittings and soak entire body in descaling acid.

21. 

No backflow preventer installed

Install appropriate backflow preventer into water line.

PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush
the chemical out of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical
strainer and replace if missing.