Troubleshooting Guide
AF 919155 • Pump Fed Sanitizer
Problem
Possible Cause / Solution
Startup
Maintenance
A) Weak pressure or will not spray
1, 2, 3, 4
5, 6
Possible Cause / Solution
Startup
Maintenance
1.
Inlet or discharge ball valves not completely open
Completely open both ball valves.
2.
Solution pressure or volume too low/inlet piping too small.
Increase solution pressure or volume.
3.
Discharge hose too long for available solution pressure, kinked or
wrong size
Straighten the hose or replace hose.
4.
Nozzle size too small (SEE REQUIREMENTS)
5.
Inlet orifice clogged
Check/clean inlet orifice for obstructions.
6.
Hard water scale or chemical build-up may have formed in the body
causing poor or no flow
Follow Preventive Maintenance instructions below, using hot
water and/or de-scaling acid. When there is no flow at all,
carefully remove fittings and soak entire body in de-scaling acid.
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods run water through the system to flush the
chemical and help prevent chemical build-up.
Printed: Thursday Jun 26th 2014
- Page 4 -