Afag IRG 1-S Translation Of Operating And Installation Instructions Download Page 5

 

R02.1 

 

04/03/2020 

Page 5 

1.2

 

Basic safety information 

This description contains the necessary information for the correct application of the 
product described below. It is intended for use by technically qualified personnel. 

Qualified personnel are persons who, because of their training, experience and posi-
tion  as  well  as  their  knowledge  of  appropriate  standards,  regulations,  health  and 
safety requirements and working conditions, are authorised to be responsible for the 
safety  of  the  equipment, at  all times,  whilst  carrying  out  their  normal  duties and are 
therefore aware of, and can report, possible hazards (Definition of qualified employ-
ees according to IEC 364). 

 

DANGER

 

 

Hazardous Voltage! Failure to observe can kill, cause serious in-
jury or damage. 

 

 

Isolate from mains  before installation or dismantling work, as well as for fuse 
changes or post installation modifications. 

 

Observe  the  prescribed  accident  prevention  and  safety  rules  for  the  specific 
application. 

 

Before  putting  into  operation  check  if  the  rated  voltage  for  the  unit  conforms 
with the local supply voltage. 

 

Emergency  stop  devices  must  be  provided  for  all  applications.  Operation  of 
the emergency stop must inhibit any further uncontrolled operation. 

 

Electrical connections must be covered. 

 

The earth connection must be checked for correct function, after installation. 

 

1.3

 

Specified use 

The units described herein are electrical controllers for installation in industrial plants. 
They are designed for power adjustment on vibratory feed equipment. 

 

NOTE 

 

Any other use is inappropriate and will result in the warranty be-
coming null and void. 

See also our General Terms of Business. 

 

 

Summary of Contents for IRG 1-S

Page 1: ...Controller IRG 1 S Translation of operating and installation instructions Copyright by Afag GmbH ...

Page 2: ...2 1 This operation instruction applies to Type Order number Controller IRG 1 S 230 V 50 Hz 50360105 115 V 60 Hz 50360106 Version of Documentation BA_IRG1 S_R02 1_EN docx Release R02 1 Date 04 03 2020 Effective from A 91087 ...

Page 3: ...echnical data 7 3 Assembly instructions 9 3 1 Installing the unit 9 3 2 Connection possibilities 9 4 Operating instructions 11 4 1 Internal Trimmers 12 4 2 Setpoint source 12 4 3 Half and full wave 12 4 4 Soft start 12 4 5 Invert enable 12 5 Maintenance instructions 12 5 1 Replacing the fuse 12 5 2 Troubleshooting and fault repair 13 6 Accessories 13 6 1 Fixture 13 6 2 Address for orders 14 7 Disp...

Page 4: ...an immediate threatening danger Non compliance with this information can result in death or seri ous personal injuries invalidity WARNING Indicates a possible dangerous situation Non compliance with this information can result in death or seri ous personal injuries invalidity CAUTION Indicates a possibly dangerous situation Non compliance with this information can result in damage to property or l...

Page 5: ...ause serious in jury or damage Isolate from mains before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for the specific application Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage Emergency stop devices must be provided for all a...

Page 6: ... internal switch see set tings An adjustable soft start timer is provided to ensure that the feeder starts up smoothly when the mains supply is switched on or the control input is enabled The controller can be enabled with a 24 Vdc signal from a PLC for example control ler runs when signal voltage is applied Supply voltage variations are eliminated by an internal compensation circuit so that a con...

Page 7: ... 04 03 2020 Page 7 NOTE Repair work must be carried out by qualified personnel only We recommend that repairs are carried out on our premises 2 2 Technical data Figure 1 IRG 1 S Fixing dimensions 163 x 52 mm ...

Page 8: ...ply frequency Output voltage VAC 40 220 20 105 Output current A 0 6 Type of protection IP IP54 Fuses 1 x 6 3 A Mains connector 2m with moulded Schuko angle plug Connector to conveyor 2m cable 3 x 1 mm with Hirschmann con nector STAK 20 Dimensions l x d x h ca mm 175 x 80 x 60 Control input Optocoupler input Contact or 24 V DC external voltage Soft start s 0 4 Environmental conditions for operation...

Page 9: ...tions 3 1 Installing the unit There are two holes on the underside for mounting the controller The holes are sep arated from the interior of the housing See Figure 1 3 2 Connection possibilities Type 230V 50Hz Figure 2 Connection possibilities ...

Page 10: ...Page 10 04 03 2020 R02 1 Type 115V 60Hz CAUTION Jumpers may only be inserted for the respective application oth erwise this may lead to a malfunction of or damage to the p c b ...

Page 11: ...ge 11 4 Operating instructions Standard settings can be made without removing the front panel The setting up components are accessed by removing the small cover on the right hand side of the front panel Figure 3 Settings ...

Page 12: ...115V Units Umin 20 V Umax 105 V 4 2 Setpoint source Selection Setpoint Potentiometer or Setpoint external control current 0 20 mA 4 3 Half and full wave The correct setting of the vibrating frequency is particularly important because the wrong frequency could cause the magnet to be overloaded This setting is made with an internal slider switch The mechanical frequency of the feed system must be ch...

Page 13: ...requency and the mains voltage must conform to one another Umax trimmer setting too low set Umax Conveyor vibrates too much mag net knocking noises Incorrect oscillation frequency setting CAU TION Magnet may have been destroyed by overheating or mechanically damaged by knocking against something Umax trimmer setting too high reset Umax if necessary Magnet heats up Incorrect mains voltage for magne...

Page 14: ...0 Sales sales afag com www afag com Switzerland Afag Automation AG Zuführtechnik Fiechtenstrasse32 CH 4950 Huttwil Tel 41 0 62 959 86 86 Fax 41 0 62 959 87 87 7 Disposal Controllers that are no longer in use should not be disposed of as complete units but dismantled into separate materials and recycled Non recyclable components must be disposed of correctly ...

Reviews: