Summary of Contents for IRG 1-MS

Page 1: ...Controller IRG 1 MS Translation of original operating instruction Copyright by Afag GmbH ...

Page 2: ... 2 2014 11 12 Release 1 1 This operation instruction applies to Type Order number Controller IRG 1 MS 230 V 50 Hz 50391018 115 V 60 Hz Version of Documentation BA_IRG1 MS_R01 1_E Release 1 1 Date 2014 11 12 ...

Page 3: ...ctions 5 2 2 Basic safety information 6 2 3 Specified use 6 3 Description of the device 7 3 1 General 7 3 2 Technical data 8 4 Assembly instructions 9 4 1 Installing the unit 9 4 2 Connection possibilities 9 5 Maintenance instructions 10 5 1 Replacing the fuse 10 6 Accessories 10 6 1 Fixture 10 6 2 Address for orders 11 7 Disposal 11 ...

Page 4: ...h the following applied harmonised standards Electromagnetic compatibility EMC Emission standard for industrial environments EN 61000 6 4 Electromagnetic compatibility EMC Immunity for industrial environments EN 61000 6 2 Upon request the manufacturer undertakes to transmit technical documents electronically to national authorities if requested Authorised representative for the compilation of the ...

Page 5: ...es an immediate threatening danger Non compliance with this information can result in death or seri ous personal injuries invalidity WARNING Indicates a possible dangerous situation Non compliance with this information can result in death or seri ous personal injuries invalidity CAUTION Indicates a possibly dangerous situation Non compliance with this information can result in damage to property o...

Page 6: ...l cause serious in jury or damage Isolate from mains before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for the specific application Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage Emergency stop devices must be provided for al...

Page 7: ...n also be operated safely at the IRG 1 S con troller CAUTION In the case of applications that require the oscillation conveyor to be switched ON and OFF constantly e g dust switching hopper control system etc the prescribed controller input must be used If the load circuit is disconnected with a switch or a relay the controller may be damaged If the controller is switched on never insert or remove...

Page 8: ... 3 2 Technical data Table 1 Technical data Type Unit IRG 1 MS Supply voltage VAC 230 115 Frequency Hz 50 60 10 Enable input VDC 24 Motor output VAC A 230 115 1 Type of protection IP54 Figure 1 IRG 1 MS Fixing dimensions 163 x 52 mm ...

Page 9: ...bly instructions 4 1 Installing the unit There are two holes on the underside for mounting the controller The holes are sep arated from the interior of the housing See Figure 1 4 2 Connection possibilities Figure 2 Connection possibilities ...

Page 10: ...e to the p c b 5 Maintenance instructions 5 1 Replacing the fuse Procedure 1 Always pull the plug out before opening the controller 2 Unscrew the housing cover screws 3 Replace the defective fuse 4 Close the housing again 6 Accessories 6 1 Fixture Table 2 Order data Type Designation Order number Fixture For one device 50205146 For two devices 50205144 ...

Page 11: ...27 490 Sales sales afag com www afag com Switzerland Afag Automation AG Zuführtechnik Fiechtenstrasse32 CH 4950 Huttwil Tel 41 0 62 959 86 86 Fax 41 0 62 959 87 87 7 Disposal Devices that are no longer in use should not be disposed of as complete units but dismantled into separate materials and recycled Non recyclable components must be disposed of correctly ...

Reviews: