Light key
Press
Light
key to turn light on. Press a second time to turn
light off. A built-in timer automatically turns light off after
2 hours, unless it has been manually deactivated first.
The “Light” indicator lights up
when light is on.
Up/Down keys
Use
Up
or
Down
key to set desired water temperature.
The temperature setting will be displayed for 5 seconds to
confirm your new selection.
The "Set Point" icon indicates that the display shows the
desired temperature, NOT the current water temperature!
Filter cycle frequency
Press
Light
key again. The display will show
Fx
, with "x"
representing the number of filter cycles per day (up to 4).
(Default: twice a day).
Use
Up
or
Down
key to change setting.
When the desired setting is displayed, press
Light
key
to confirm. A filter cycle will start immediately.
The “Filter” indicator lights up
when a filter cycle is on.
Purge cycle frequency
Press and hold
Light
key until the display shows
Fx
, with "x"
representing the number of purge cycles per day (up to 4).
Use
Up
or
Down
key to change setting.
When the desired setting is displayed, press
Light
key to confirm. A purge cycle will start immediately.
The “Filter” indicator lights up
when a purge cycle is on.
Programming purge cycles
To program the purge cycles, you must select the frequency. During a purge cycle, all pumps
and the blower run for one minute. To set purge cycles:
Off Mode
This mode allows you to stop all outputs for 30 minutes to
perform a quick spa maintenance.
Press and hold
Key 1
key for 5 secs to activate the Off mode.
Quick press
Key 1
key to reactivate the system before the ex-
piration of the 30-minute delay.
While the Off mode is engaged, the display will toggle
between
OFF
and the water temperature.
Setting the temperature display units
Quick press
Light
key again. The display will show either
°F
or
°C
.
Use
Up
or
Down
key to change units.
Press
Light
key a last time to go back to normal mode.
°F
= Fahrenheit -
°C
= Celsius
Setting filter cycle duration
Press and hold
Light
key until the display shows
dxx
, with
"xx" representing the duration in hours. (Default: 2 hours).
Use
Up
or
Down
key to change setting.
0 = no filtration
24 = continuous filtration
Note: it's not recommended to set this to "0".
OFF
Programming
the purge / filter cycles
Programming filter cycles
Depending on system configuration the system performs either purge cycles or filter cycles.
To program the filter cycles, you must enter these parameters: duration and frequency.
During a filter cycle, pumps & blower run at high speed for one minute to purge the
plumbing. Pump 1 or CP then runs at low speed for the remaining of the cycle.
Water temperature regulation
In a regulation cycle, the system first gener-
ates water flow through the heater housing
and the plumbing, in order to ensure accu-
rate water temperature readings as well as
avoiding heater activation in dry conditions.
After verifying pump activation and taking a
water temperature reading if required, the
system automatically turns the heater on to
reach and maintain water temperature at
Set Point.
The “Heater” indicator lights up when
the heater is on. It flashes when there
is a request for more heat but the
heater has not yet started.
Cooldown
While performing this task, the heater is not
allowed to turn on and its icon flashes.
Smart Winter Mode
Our Smart Winter Mode protects your
system from the cold by turning pumps on
several times a day to prevent water from
freezing in pipes.
The “Smart Winter Mode” indicator
lights up when the Smart Winter Mode
is on.