Quick Guide
VX2000
13
GB
•
G.821 data: SES (severely errored seconds), DM (degraded minutes), ES
(errored seconds), US (unavailable seconds) in absolute value and percentage,
result of the PASS/FAIL test according the G.821 quality targets.
2 SMART STATUS
To have a complete description of the Smart Status feature, see the specific
chapter in the D2000Pro User’s Manual.
2.1 V/X Interface status
The 2
nd
page, relative to V/X INTERFACE access, shows the activity of the used
interface.
1
Goes to page 2.
The Clock Rx value, is displayed on the Status pages only if the
clock value has been set as ‘Looped’, in the common setup.
Selecting the relative interface field and pushing ENTER, it is possible to insert a
loop on the data, the device will send, in transmission, the data received from the
remote. Perform the same operation to remove the loop.
The 3
rd
page shows the state of criteria toward DCE and DTE
2
Goes to page 3.