TECHNICAL SPECIFICATION
COMPONENTS AND MODULARITY
• Rack:
Up to 7 subracks on each
ETSI rack (ETSI ETS-300 119)
• Subrack: 8 line modules (AF3005)
one supervisory module (AF3003)
triple redundant dc battery power inputs
• Line Module (AF3005):
4 ShDSL and 4 E1 (G.703/G.704) I/F
an independent dc/ac converter
program code and configuration files
• Supervisory module (AF3003):
RS-232 and Eth 10BaseT I/F for :
Alarm reporting, event monitoring
Line module configuration and sw upgrade
E1 INTERFACE
• E1 port, full E1 UNI
(as per af-phy-0064_000) and fractional
E1UNI (as per af-phy-0130_000) are
supported
• TX
Line Code: HDB3
Nominal Impedence:75 Ohm
• RX
Line Code: HDB3
Nominal Impedence:75 Ohm
SNR: > 18dB
Jitter Tolerance: ETSI TS 101 135
Aethra, the Aethra logo and AF 3400 are trademarks, registered trademarks, or service marks of Aethra SpA Telecommunications in Italy, the United States, and/or other countries. All other company and product names may be
registered trademarks or trademarks of their respective owners. Information furnished by Aethra SpA Telecommunications and Aethra, Inc. in this datasheet is believed to be accurate. Products sold and licensed by Aethra SpA
Telecommunications and Aethra, Inc. are covered by warranty and patent indemnification provisions appearing in its purchase and license agreements. Aethra SpA Telecommunications and Aethra, Inc.
reserve the right to discontinue production and change specifications and prices at any time without notice. Copyright ©2004 Aethra SpA Telecommunications - All rights reserved. Additional regional offices are
located on our website:
www.aethrausa.com.
For further details about technical specifications please see “Products” on
www.aethra.com
SHDSL LINE INTERFACE
• ETSI TS 101 524-1 and -2
SERVICE FUNCTIONS
• Frame Relay to ATM Interworking:
- FR/ATM PVC service interworking
(SIW) according to FRF. 8.1 either in
transparent or translated mode
- FR/ATM PVC network interworking
(NIW) according to FRF.5; supported
multiplexing modes:
(a) One-to-One: Each FR logical
connection is mapped to a single ATM
PVC
(b) Many-to-One: Multiple FR logical
connections are multiplexed into a single
ATM PVC
- Up to 128 NIW and SIW channels
supported
- Up to 10 Frame Relay Traffic Classes
configurable and usable for all the
FR-PVCs
- PVC management by Link
Management Interface (LMI) compliant
to ITU-T Q.933 Annex A or T1.617
(Annex D) and compatible with
CISCO-like implementations
• Cell Bridging:
- AF3400 acts as a VP/VC ATM switch
- On E1 port, full E1 UNI
(as per af-phy-0064.000) and fractional
E1 UNI (as per af-phy-0130.000)
supported
POWER
• Input Voltage 36-72 Vdc
• Max Power Consumption < 55 W
ENVIRONMENT
• Protections:
ITU - K20, ITU – K21
• Safety:
EN 60950
• EMC:
ETSI EN 300 386,
EN 55022, EN 55024
• Operating conditions:ETSI 300 019-1-3,
class 3.2
• Transport conditions: ETSI 300 019-1-2,
class 2.2
• Storage conditions: ETSI 300 019-1-1,
class 1.2
DIMENSIONS
• Width 600
mm
• Deep 300
mm
• Height 2200
mm
Aethra SpA
Telecommunications
via Matteo Ricci 10
60020 Ancona - Italy
Tel39.071.218981
Fax +39.071.887077
Video 1
+39.071.2189160
Video 2
+39.071.2189701
Email: [email protected]
www.aethra.com
Aethra, Inc.
701 Brickell Avenue
Suite 1390
Miami, FL 33131 USA
Tel1.305.375.0010
Toll Free (US only)
1.888.4.AETHRA
Fax +1.305.375.0655
Video +1.305.577.3524
Email: [email protected]
Code 071073030GB Rev. 0 (02/04)