AETEK XE52-120-TX Quick Installation Manual Download Page 2

LEDs 

PoE

Yellow ON

PoE: Power port is connected to PD

LAN

Green flash

LAN: Data is being transmitted or received. 

OFF

No connection

PWR

Yellow ON

Power is supplied

LINK

Green ON

Rx and Tx EPoC adapter is connected. 

Distance/Power Chart 

NOTE:

1. The numberts comply using RG6 coaxial cables. 

2. The length of network cable for camera connection is 1m CAT5e cable. 

3. The power delivery will vary on the quality of coaxial cable due to 

resistance. 

AETEK INC.

3F, No.192, Lien-Cheng Rd., Chung-Ho, New Taipei City, 235, Taiwan, R.O.C.

|

T

:

 +886-2-82452822

|

W

:

 www.aetektec.com

|

E

:

 [email protected]

All specifications are subject to change without noice. 

Copyright © 2020 AETEK INC. All rights reserved. 

To disconnect a LAN cable, loosen the cable

gland and pull the cable against the socket

wall towards the side of the locking tab. 

  

 Outdoor LAN Port

IMPORTANT - 

1.  Fit a BNC plug to the coaxial cable

2.  Thread the coaxial cable through the cap(A) & grip(B)

3.  Split rubber(C), rubber have two sizes for meet 4.5~6.5mm or 6~8mm 

coaxial cable.

4.  Fit the split rubber(C) over the coaxial cable

5.  Thread the coaxial cable through the body(D)

6.  Fit the washer(E) to the XE62-120-TX connector

7.  Plug the BNC connector on the coaxial cable into the XE62-120-TX

8.  Hold XE62-120-TX and then screw the body(D) onto the XE62-120-TX 

connector tighten firmly

9.  Push rubber(C) in the grip(B) and screw the cap tighten firmly. The coaxial 

cable is sealed when the rubber(C) & grip(B) bulges to the edge of the 

cap(A). The BNC Male connector needs <38mm form coaxial cable.

Outdoor EPoC LINK Port Connector Assembly

Washer (E)

Body (D)

Rubber (C)

Grip (B)

Cap (A)

Rubber (C)

Rubber (C)

Split

Length of Coaxial Cable
300m

34.72W

500m

25.2W

800m

13.11W

1000m

10W

1200m

9.66W

1200m ~ 2400m

Data only (100Mbps)

NOTE: 

The XE62-120-TX Outdoor EPoC Adapter must be 

grounded using a ground wire between the

 

ground screw 

and earth ground.   

     IMPORTANT:

Ground screw

* Make sure the grouning

resistance is lower than 

0.5

Ω.

XE62-120-TX

Reset to default 15 seconds

Mode/Reset Button

Join Button

• Press the Join button for 1-3 seconds on both Local and Remote Extenders to Link them.

• Press the Join button on the Remote Extender for 5-8 seconds to disconnect the Link between the Extenders

• Press the Join button for 10~15 seconds to reset the Extender to default.