it in case scalding.
3. Do not put metal objects into the inverter, this could cause electric shock.
4. Do not touch the metal of the socket while insert the plug to the socket of the
inverter.
5. Keep the inverter away from explosives.
6. Keep all AC electric equipment away from the inverter, it will damage the
inverter and also may cause electric shock.
Protect function and Restart work method;
State description
Function
LED light
Alarm
AC output
Restart work method
Input low
voltage
alarm
Green on
Red off
Alarm
AC has output
When the voltage of
the battery returns to
the related range, the
alarm will stop
automatically
Input low
voltage shut
down
Green on
Red on
Alarm
No AC output
When the voltage of
the battery returns to
the related range, the
inverter will start
working, green light
will go on, red light will
go off.
Input over
voltage
protection
Green on
Red on
No
alarm
No AC output
When the voltage of
the battery returns to
the related range, the
inverter will start
working, green light
will go on, red light will
go off.
Over load
protection
Green on
Red on
No
alarm
No AC output
Reduce the load to
acceptable range the
inverter will start
working, green light
will go on, red light will
go off.
Over
temperature
protection
Green on
Red on
Alarm
No AC output
When the inside
temperature returns to
acceptable range the
inverter will restart
work, green light will
go on, red light will go
off.
Output short
circuit
Green on
Red off
No
alarm
No AC output
When short circuit
removed, the inverter
will start to work
automatically