AeroVironment EV Solutions EVSE-RS Plug-in User Manual Download Page 26

44

45

C

H

A

P

T

ER
 5

  

l

  

W

AR

R

AN

T

Y

C

H

A

P

T

ER
 5

  

l

  

S

P

E

C

IF
ICA
T

ION
S

44

SPECIFICATIONS

Model 

EVSE-RS Plug-in 

Connector 

SAE J1772 compliant

Car Charging Dock communication protocol

SAE J1772 compliant

Dimensions 

12” H x 12” W x 8” D approximately

Voltage 

either 240 VAC split phase and neutral grounded or 208 VAC 2 phases and neutral grounded

Current output power 

30 Amp Maximum

Circuit breaker rating 

40 Amp. Do NOT use a Class A circuit breaker with the EVSE-RS Plug-in Charging Dock

Frequency 

50Hz / 60Hz

Power draw at idle 

Less than 5 Watts

Weight with 25 ft. cable 

19.2 lbs (8.71Kg)

Temperature-Operating 

-22°F to +122°F (-30°C to +50°C)

Temperature-Storing & Transporting 

-40°F to 140°F (-40°C to +60°C)

Humidity 

Up to 90% non-condensing

Environmental rating 

Type 3R enclosure, Raintight with mounting plate

Regulatory compliance 

UL and cUL listed and CSA compliant. U.S. installs, FCC part 15, subpart B. Canadian installs 

must comply with the Electric Code for Canada. FCC part 15, subpart B 

 Specifications are subject to change without notice.

The AV Home Charging Dock Model EVSE-RS Plug-in (“Charging Dock”) 
is warranted to the original purchaser to be free of defects in material 
and workmanship for a period of thirty-six (36) months from the date of 
shipment. THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN 
BY AV WITH RESPECT TO THE Charging Dock. AV UNDERTAKES 
NO RESPONSIBILITY FOR THE QUALITY OF THE Charging Dock 
EXCEPT AS OTHERWISE PROVIDED IN THE AGREEMENT AND THIS 
WARRANTY. OTHER THAN EXPRESS AND/OR IMPLIED WARRANTIES 
REQUIRED BY APPLICABLE LAWS OR WHICH ARE REQUIRED TO 
EXTEND FOR A LONGER PERIOD, THERE ARE NO WARRANTIES THAT 
EXTEND BEYOND THIS LIMITED WARRANTY AND ANY REQUIRED 
WARRANTIES ARE LIMITED IN DURATION TO THE WARRANTY PERIOD.

To the extent permitted by applicable laws: (a) AV’s total warranty expense 
with respect to any Charging Dock is limited to a maximum of the original 
purchase price of that Charging Dock as applicable to a warranty claim; 
(b) AV’s liability under this warranty shall be limited to the repair or 
replacement, at AV’s option, of defective Charging Docks or defective 
component parts; and (c) AV will not be liable for repair, replacement, 
service call, de-installation or installation costs for Charging Docks not 
covered by this warranty, which shall be the responsibility of the Buyer. 
Coverage under the terms of this limited warranty is not transferable to  
any other party. 

This limited warranty does not cover service calls to correct the installation 
of your Charging Dock, instruction to you on how to use your Charging 
Dock, costs associated with de-installing the Charging Dock, shipment of 
the Charging Dock to AV for repair or replacement and shipment of the 
repaired or replaced Charging Dock back to your home, or re-installation of 
the repaired or replaced Charging Dock.

This warranty shall be voided by damage or excessive wear to the Charging 
Dock caused by abnormal operating or environmental conditions (including 
exposure to acid, chemical fumes, metallic dust or extreme temperatures), 
accident, abuse, damage, misuse, vandalism, unauthorized alteration or 
repair, utility surges, or if the Charging Dock was not installed, operated, 
serviced or maintained in strict compliance with the Home Charging Dock 
Model EVSE-RS Plug-in User’s Manual and other printed instructions 
provided by AV. No installation services warranty applies under these 
Terms. Any evidence of an attempt to disassemble or reverse engineer the 
Charging Dock will void this warranty

WARRANTY

Summary of Contents for EV Solutions EVSE-RS Plug-in

Page 1: ...TRICIAN Leave this User Guide with the EVSE RS customer for future reference Model EVSE RS Plug In not for outdoor installation USER GUIDE 100 electric AeroVironment EV Solutions Charging Dock Model E...

Page 2: ...EVSE RS Plug in are repre sentative production models may vary No portion of these materials may be duplicated used or disclosed without prior written permission from AeroVironment Inc Disclaimer This...

Page 3: ...DEL EVSE RS Plug in SERIAL NUMBER S N On label on underside of Charging Dock enclosure housing PURCHASE DATE TABLE OF CONTENTS GETTINGSTARTED 1 Introduction 2 Electricvehiclecompatibility 3 Features 3...

Page 4: ...CHAPTER 1 GETTING STARTED iv iv...

Page 5: ...t is for indoor use ONLY It is recommended that the unit be wall mounted 2 C H A P T E R 1 l G E T T I N G S T A R T E D 3 C H A P T E R 1 l G E T T I N G S T A R T E D ELECTRIC VEHICLE COMPATIBILITY...

Page 6: ...ixed to your Charging Dock IMPORTANT SAFETY INSTRUCTIONS Please read these important safety instructions and the charging instructions in your vehicle owner s manual before charging your electric vehi...

Page 7: ...e To clean the Charging Dock wipe the Charging Dock with a clean cloth dampened with water or a mild detergent solution suitable for use on automobile paint Turn off power at the circuit panel before...

Page 8: ...fects or other reproductive harm CAUTION To reduce the risk of electric shock connect only to properly grounded outlets ALWAYS position the Charging Dock output cable so that it will not be driven ove...

Page 9: ...evice complies with Part 15 of the FCC Rules Operation is subject to the following two conditions This Class B digital apparatus complies with Canadian ICES 003 1 This device may not cause harmful int...

Page 10: ...d with excessive force The Charging Dock cable should be coiled up on the hanger when not in use to minimize potential cable damage and to eliminate the possibility of tripping over the cable If the c...

Page 11: ...CHAPTER 2 OPERATION 14 C H A P T E R 1 l G E T T I N G S T A R T E D...

Page 12: ...nterrupts the charging cycle at any time If vehicle is connected to the Charging Dock press START to resume charging STORAGE Connector inserts into Charging Dock here and stays in place for storage wh...

Page 13: ...connector from the Charging Dock CHARGING YOUR VEHICLE 1 CHECK INDICATOR LIGHTS First make sure the POWER PRESENT and READY TO CHARGE lights are ON as shown below This means that the Charging Dock is...

Page 14: ...time if the driver has set a vehicle charging timer for scheduled charging POWER PRESENT VEHICLE CONNECTED and the VEHICLE CHARGING lights stay on when charging VEHICLE CHARGING light blinks when the...

Page 15: ...interrupt charging at any time using one of the two following methods If you want to temporarily stop charging and restart later without having to remove the coupler then the buttons are the preferre...

Page 16: ...esume charging pdf pg 15 POWER PRESENT READY TO CHARGE VEHICLE CONNECTED VEHICLE CHARGING TROUBLE STOP PAUSE START RESUME BLINKING OFF LATCH RELEASE 7 REMOVE AND RETURN CONNECTOR TO CHARGING DOCK When...

Page 17: ...ter the fourth attempt the Charging Dock will shut down and the TROUBLE light will be ON pdf pg 15 POWER PRESENT READY TO CHARGE VEHICLE CONNECTED VEHICLE CHARGING TROUBLE THIS LIGHT GOES OUT WHEN AUT...

Page 18: ...ng Dock TIME OF USE METERING Many electric utilities have been actively promoting the use of EVs and have developed specific utility rates to promote off peak charging of these vehicles This allows th...

Page 19: ...ice on the Charging Dock or the Charging Dock Warranty may be invalidated Contact Customer Support for service NOTE NOTE 30 31 C H A P T E R 3 l T R O U B L E S H O O T I N G POWER PRESENT LIGHT DOES...

Page 20: ...the panel and discontinue using immediately and contact Customer Support for service 3 Inspect vehicle receptacle for damage If damaged discontinue using immediately and report the problem to your nea...

Page 21: ...not deliver power to the vehicle The problem must be corrected before charging starts or resumes There are two scenarios for a solid TROUBLE light NOTE 1 Turn power OFF then ON at circuit breaker or...

Page 22: ...eat source 3 Provide shade from direct sunlight 4 If the fault persists contact Customer Support for service TROUBLE LIGHT IS RAPIDLY BLINKING Press STOP A TROUBLE LIGHT GOES OFF 1 Press START 2 TROUB...

Page 23: ...CHAPTER 4 INSTALLATION C H A P T E R 3 l T R O U B L E S H O O T I N G 38...

Page 24: ...ply with the provisions of the National Electric Code NEC and all local codes for the U S or must comply with Canadian Electric Code for Canada Charging Dock must be installed using 1 40 amp circuit b...

Page 25: ...CHAPTER 5 APPENDIX 42 C H A P T E R 4 l I N S T A L L A T I O N...

Page 26: ...HIS LIMITED WARRANTY AND ANY REQUIRED WARRANTIES ARE LIMITED IN DURATION TO THE WARRANTY PERIOD To the extent permitted by applicable laws a AV s total warranty expense with respect to any Charging Do...

Page 27: ...g 44 F features 3 17 front panel cover 16 G ground fault circuit 11 I installing 6 39 L latch release 17 19 20 25 M model ii N NEMA Type 3R 44 O owner s record ii P power outage recovery 27 R regulato...

Page 28: ...Customer Support Phone Number US 1 877 NO GAS EV 1 877 664 2738 Canada 1 800 387 0122 100 electric 21327 03 Rev 2...

Reviews: