![Aerotech Soloist CP 10 Hardware Manual Download Page 21](http://html1.mh-extra.com/html/aerotech/soloist-cp-10/soloist-cp-10_hardware-manual_2863050021.webp)
Introduction
Soloist CP
1.2.2. Power Dissipation
The amplifier power dissipation under continuous power supply and output current conditions is shown in
. The values on the graph represent the peak current that the amplifier would provide during
operation. When the bus voltage and output current are known, the amplifier power dissipation is found using
this graph.
shows the maximum recommended ambient temperature as a function of amplifier
power dissipation. Use this graph along with the power dissipation obtained from the first graph to determine
the maximum ambient temperature. If the result is lower than the known operating ambient temperature,
additional measures are required to cool the Soloist CP. Mounting it to a large metal plate for extra heat-
sinking and providing additional fan flow are suggested.
Figure 1-3:
Power Dissipation vs. Output Current
Figure 1-4:
Ambient Temperature vs. Power Dissipation
EXAMPLE:
320 VDC Bus operation at 5 A
Power Dissipation = 47 Watts
Maximum Ambient Temperature = 54°C
www.aerotech.com
Chapter 1
21
Summary of Contents for Soloist CP 10
Page 1: ...Revision 4 09 00 Soloist CP Hardware Manual...
Page 14: ...Soloist CP Quick Installation Guide 14 www aerotech com This page intentionally left blank...
Page 24: ...Soloist CP Introduction 24 Chapter 1 www aerotech com This page intentionally left blank...
Page 90: ...90 Chapter 3 www aerotech com Figure 3 7 Digital Inputs Soloist CP IO Expansion Board...
Page 100: ...100 Chapter 4 www aerotech com Soloist CP Accessories This page intentionally left blank...
Page 108: ...Soloist CP Revision History 108 Appendix B www aerotech com This page intentionally left blank...