![Aerotech HPe 150 Hardware Manual Download Page 25](http://html1.mh-extra.com/html/aerotech/hpe-150/hpe-150_hardware-manual_3049258025.webp)
Installation and Configuration
Soloist HPe 150/200
Chapter 2: Installation and Configuration
2.1. Power Connections
The Soloist HPe 150/200 has two AC input connectors; one for control power and a second for motor power.
For a complete list of electrical specifications, refer to
N O T E :
The machine integrator, OEM or end user is responsible for meeting the final protective ground-
ing requirements of the system.
2.1.1. Control Supply Connections
N O T E :
This product requires two power supply connections. The Motor Supply and Control Supply
must both be connected for proper operation.
The control power supply input allows the Soloist HPe 150/200 to maintain communications if the motor
power is removed, such as in an Emergency Stop condition. The control power supply requires a minimum of
85 VAC input to operate properly. The AC1 input is internally fused. The AC2 input is not internally fused but
can be connected to a voltage source other than Neutral if an external 2 A time-delay fuse is used.
Although the control power supply contains an internal filter, an additional external filter located as close as
possible to the Soloist HPe 150/200 may be required for CE compliance (Aerotech recommends Schaffner
FN2080).
Figure 2-1:
Control Supply Connections
Table 2-1:
Control Supply AC Input Wiring
Pin
Description
Recommended Wire Size
(1)
AC1
Line (L): 85-240 VAC Control Power Input
0.8 mm
2
(#18 AWG)
AC2
Neutral (0V) or 85-240 VAC Control Power Input with external
fuse
0.8 mm
2
(#18 AWG)
Protective Ground (Required for Safety)
0.8 mm
2
(#18 AWG)
(1) Refer to local electrical safety requirements to correctly size external system wires.