4.5. Troubleshooting
Symptom
Possible Cause and Solution
Stage will not move
Brake not released (if equipped with brake; refer to stage documentation).
In Limit condition. Check limits (refer to
Chapter 3: Electrical Installation
) and
refer to the Controller documentation for polarity and compatibility
requirements (Example: voltage requirements).
Controller trap or fault (refer to the Controller documentation).
Stage moves
uncontrollably
Encoder (sine and cosine) signal connections (refer to
and Controller documentation).
Motor Connections (refer to
Chapter 3: Electrical Installation
and the Controller
documentation).
Stage oscillates or
squeals
Gains misadjusted (refer to the Controller documentation).
Encoder signals (refer to the Controller documentation).
4.5. Troubleshooting
ECO225SL Hardware Manual
56
www.aerotech.com