1.2. Mechanical Specifications
1.2.1. Mounting and Cooling
The drive must be installed in an enclosed control cabinet suitable for installation of power
equipment. A minimum enclosure rating of IP54 is required to comply with safety standards. Make
sure that there is sufficient clearance surrounding the drive for free airflow and for the routing of
cables and connections. Consideration for items such as line reactors, line filters, and motor chokes
or inductance should be made during the initial cabinet design phase.
Table 1-3:
Mounting Specifications
XL2e
Customer-Supplied Enclosure
IP54 Compliant
For DIN Rail Mounting,
refer to
Section 4.1. DIN Rail Mounting
Weight
1.0 kg
Mounting Hardware
M3.5 [#6] screws (four locations, not included)
Mounting Orientation
Vertical (typical)
Dimensions
Refer to
Minimum Clearance
Airflow
~25 mm
Connectors
~100 mm
Operating Temperature
Refer to
Section 1.3. Environmental Specifications
Drive IP Rating
IP20
iXL2e/XL2e
Hardware Manual
22