AeroScout T2u Wi-Fi Ultrasound Tag
Tag Maintenance
14
3.
Carefully remove the old battery from the battery holder.
Note
Do not use a metal object to remove the battery.
4.
Install a new 3.6V lithium Thionyl Chloride ½ 'AA' size battery in the battery holder.
WARNING: Use only batteries listed in Table 1 or batteries that have been
approved by AeroScout. There is a danger of fatal tag damage if the battery
is replaced incorrectly or by an incorrect type. Dispose used batteries
according to the instructions.
5.
Close the rear panel.
6.
Activate the tag.
7.
Dispose of the old lithium Thionyl Chloride battery properly.
WARNING: Local regulations vary. Federal regulations allow up to 100
kg./month of lithium thionyl chloride batteries to be disposed in common
landfill. All leads (the terminals) should be taped to prevent short circuit.
The user is responsible for safe disposal.
Table 1 presents the approved battery types for the T2u tag:
Manufacturer
Battery Part Number
Tadiran
TL-5902
Xeno Energy
XL-050F
Sonnenschein
SL-350
Saft
LS-14250C
Table 1
– T2U Tag Approved Battery Types
Tag Battery Life
T2u Tag battery can last up to 3 years depending on the extent of motion and on how
frequent the tag stays within the ranged of an ultrasound Exciter.