WELCOME

 

Congratulations! You are now the proud owner of the most user 

friendly, effective Furnace Filter System, the “AEROPURE 
WHFS”. Your AEROPURE  continuous filtration system helps 

reduce the many problem-causing pollutants and allergies that 
can linger in your home. The patented continuous filtration 
system not only keeps your indoor air clean, but more so 
optimizes your air flow which would result in reaching your 
preferable temperature faster hence reducing your energy cost. 

AEROPURE is dedicated to our customers and we pride 
ourselves on the quality and performance of our products. If you 
have any questions, comments, need service, or parts, please 
call your local authorized dealer or call one of the TOLL- FREE 
numbers on the back of this manual for the Distributor nearest 
you. Please, take a few moments to read all of the sections in 
this manual and familiarize yourself with your new AEROPURE. 
We hope you will enjoy all the benefits of clean and efficient air 
filtration. 

TABLE OF CONTENTS

 

Section A 

 IMPORTANT SAFETY INSTRUCTIONS .........3 

Section B 

 TECHNICAL SPECIFICATIONS......................3 

Section C 

 PARTS DESCRIPTIONS.................................4 

Section D 

 INSTALLATION INSTRUCTIONS ...................5 

Section E 

 OPERATION INSTRUCTIONS.................14,15 

Section F 

 FILTER REPLACEMENT..........................16,17 

Section G 

 TROUBLE SHOOTING GUIDE.....................18 

Section H 

 WARRANTY ..................................................19

 

SECTION A –

 

IMPORTANT SAFETY INSTRUCTIONS

 

When using an electrical appliance, basic precautions should always be 

followed, including the following: 

READ ALL INSTRUCTIONS BEFORE USING YOUR AeroPure WHFS

 

 

WARNING: 

To reduce the risk of fire, electric shock or injury: 

• Do not use outdoors or on wet surfaces

 

• Do not use with damaged cord or transformer

 

• If the supply cord is damaged, it must be replaced by the

 

manufacturer 

• Do not unplug the transformer by pulling on cord. To 

unplug, 

grasp the transformer, not the cord 

• 

Do not handle transformer with wet hands 

 

SECTION B –

 

TECHNICAL SPECIFICATIONS

 

Motor

: 24 VDC 

Transformer

: Class 2 

Input: 120V AC 60Hz 33.5W 

Output: 24V AC 833mA 

UL No. 38H3 

Filter

: Electrostatic Charged Media - UL No. R18143. 

Several filters available at your dealer. Refer to 

filter packaging for product specification. 

Construction

: Anodized Aluminum frame, ABS control 

box, Polystyrene cover 

Warranty

: See warranty for details - Page 19

 

Summary of Contents for WHFS

Page 1: ...allation Operation Manual Automatic Whole Home Filtration System Patented 6 632 269 6 491 735 6 402 822 6 743 282 For Residential Forced Air Furnace Only Website www AeroPure us US Toll Free 1 800 281 6242 ...

Page 2: ...ion A IMPORTANT SAFETY INSTRUCTIONS 3 Section B TECHNICAL SPECIFICATIONS 3 Section C PARTS DESCRIPTIONS 4 Section D INSTALLATION INSTRUCTIONS 5 Section E OPERATION INSTRUCTIONS 14 15 Section F FILTER REPLACEMENT 16 17 Section G TROUBLE SHOOTING GUIDE 18 Section H WARRANTY 19 SECTION A IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance basic precautions should always be followed inclu...

Page 3: ...LING LEGS 12 2 10 32 HEX NUT 13 1 Air SAMPLING TUBE 14 1 162038 RETAINING SPRING 15 CONTROL BOX AND CARTRIDGE SUPPORT FRAME ASSEMBLY SECTION D INSTALLATION INSTRUCTIONS STEP 1 Cold Air Return Determine the air duct cold air return in relation to the furnace before assembling and installing the AeroPure Filter STEP 2 Modifying Cartridge Frame Assembly Make sure the RH or LH label is upward dependin...

Page 4: ...rame for proper support At this time thread the knurled thumb knob in to the top of the frame This will secure the top of the cartridge cover STEP 6 Control Box Frame Assembly Place the control box on the frame so that the 2 positioning legs rest in the U channel Make sure the holes are lined up for the quick connect pins provided to go through The ring should be against the U channel Now assemble...

Page 5: ...ig 7A Snap in the new filter cartridge between the springs Top spring has the idler that fits inside the roll end cap Fig 7A shows the filter media installed for both R H and L H applications The white arrows show the direction the take up reel will turn for each STEP 8 Feeding The Filter Media Using the filter paper with white taped end as a lead feed the paper as shown in figure FIG 8A for right...

Page 6: ...STEP 8 Feeding The Filter Media continued Hold the white taped lead of the filter paper feed the paper as shown in figure FIG 8C L ...

Page 7: ......

Page 8: ......

Page 9: ...AeroPure AeroPure ...

Page 10: ...rranty does not cover Use of the AeroPure for commercial industrial or other non household purposes Damage occurring through misuse or negligence Damage caused by the use of a current or voltage other than 24 volts 833Amp transformer provided Damage resulting from service work performed by parties other than AeroPure or the authorized dealers Cost of transportation to our offices or service calls ...

Reviews: