Safety Notices

 

1.  Heed all warnings and follow all instructions in this manual.

 

2.  Do not use this apparatus near water.

 

3.  Clean only with a dry cloth.

 

4.  Do not block ventilation openings. Install in accordance with instructions.

 

5.  Do not install near any heat sources such as radiators, heat registers, stoves or another 

apparatus that produces heat.

 

6.  Do not defeat the safety purpose of the polarized or grounding type plug. If the provided 

plug does not fit into the outlet, consult your Reseller.

 

7.  Protect the power cord from being walked on or pinched, particularly at plugs, conven-

ience receptacles, etc.. Unplug the AC mains cord as well as all other connecting cables 
during transportation.

 

8.  Only use attachments and accessories specified by Aeron or your Authorized Aeron 

dealer.

 

9.  Use a surge protector on the main AC-Line to this component as well as all other compo-

nents connected to this product. Unplug this apparatus during lightning storms or when 
unused for long periods of time.

 

10.  Refer all servicing to qualified service personnel. NO USER SERVICEABLE PARTS INSIDE. 

Owner may change tubes. 

OTHER SAFETY CONSIDERATIONS 

1. 

ALWAYS

 disconnect your entire system from the AC mains before connecting or disconnect-

ing any cables, or when cleaning any component. To completely disconnect this apparatus 
from the AC mains, disconnect the power supply cord plug from the AC receptacle.

 

2. 

NEVER 

use flammable or combustible chemicals for cleaning audio components.

 

3. 

NEVER

 wet the inside of this component with any liquid. If a liquid substance does enter 

your unit, immediately disconnect it from the AC mains and take it to your Aeron Dealer for 
inspection.

 

4. 

NEVER

 spill or pour liquids directly onto this component.

 

5. 

NEVER 

block air flow through ventilation slots or heat sinks.

 

6. 

NEVER

 bypass any fuse or replace any fuse with a value or type other than those specified.

 

7. 

NEVER 

expose the LP-X1 to extremely high or low temperatures. If the LP-X1 has been taken 

out of storage from an unheated environment, let the unit acclimate to room temperature be-
fore making any connections and applying power to the unit.

 

8. 

ALWAYS

 keep electrical equipment out of reach of children. Do not handle the tubes when 

hot, or wet them.  Only touch the tubes only when they are cold and the unit is unplugged 
from its source of AC Power.

 

9. 

ALWAYS 

unplug sensitive electronic equipment such as this unit during lighting storms.

 

Summary of Contents for LP-X1

Page 1: ...1 LP X1 MM MC Audiophile Grade Tube Phono Preamplifier Manual Rev 1 1 2016 USER MANUAL...

Page 2: ...your System 6 Connections AC Power Connection 7 Rear Panel Connections 7 Operation Power up Procedure 8 Front Panel Control Function 9 Maintenance Tube Replacement 10 Servicing 10 Cleaning 10 Disposa...

Page 3: ...been designed to provide you many years of playback Before use we encourage you to please read this manual thoroughly to properly acquaint yourself with its features We hope you enjoy listen ing to A...

Page 4: ...On Off Button 2 MM or MC Input Selector 3 Subsonic Filter Selector 4 MM Capacitance Selector 5 MC Impedance Selector 6 Gain Control Rear Panel 1 MC Input 2 MM Input 3 Grounding Terminal 4 RCA Output...

Page 5: ...HER SAFETY CONSIDERATIONS 1 ALWAYS disconnect your entire system from the AC mains before connecting or disconnect ing any cables or when cleaning any component To completely disconnect this apparatus...

Page 6: ...lastomer feet provide adequate spacing only from a smooth hard surface Never operate the unit while it is sitting on a surface such as a rug or carpet If the unit is to be operated in an enclosed equi...

Page 7: ...gh quality power cords The LP X1 utilizes a compatible grounding system that generally does not re quire a ground lifter adapter plug on the AC power cord to minimize hum The power cord supplied with...

Page 8: ...LP X1 wait at least five minutes before turning it on again This brief cool down period will reduce stress on the output tubes and potential damage to them Aeron does not recommend leaving your LP X1...

Page 9: ...ce is 47pF For MC phono cartridge appeared MC Impedance need to be select Please check your MC cartridge specification normal MC impedance is 100ohms Level Output level can be adjust on front Panel Su...

Page 10: ...e r o n C u s t o m e r S e r v i c e E m a i l i n f o l h e c o m h k o r postmaster stereoland info Cleaning To maintain the visual appearance of your LP X1 occasionally wipe the front panel and t...

Page 11: ...eron products sold by them The specific terms and remedies for fulfillment of the Limited Warranty may vary from country to country Warranty service should normally be obtained from the importing reta...

Page 12: ...ve s including all applicable amendments Power Supply Input 50W Voltage Range 100 120V 220 240V Max Current Draw Indicated 50W Power Consumption 50W Distortion Spec 0 07 1kHz Tube Compliment 1 ECC85 6...