24
Inverter board alarm codes KHP0040 12kW unit only
(Fig. 14)
Faults of the inverter can be diagnosed by LED indications
on the cycle control P.C. board of the outdoor unit. Utilize
them for various checks.
Before a check, confirm each bit of the DIP switch is set
to OFF position.
System test
LED indication and code checking
LED indication
Cycle control P.C. board
Cause
LED indication
D800 D801
D802 D803
¢
l
l
l
Heat exchanger sensor (TE) error
l
l
¢
l
Suction sensor (TS) error
¢
¢
l
l
Hot gas discharge sensor (TD) error
l
¢
l
¢
High-pressure protection error
l
¢
l
l
Outdoor air temperature sensor error (TO)
¢
¢
¢
l
Outdoor motorised fan error DC
¢
l
l
¢
Communication error between IPDU (Abnormal stop)
l
¢
l
¢
High-pressure release operation
l
¢
¢
l
Discharge temp. error: hot gas is too high
¢
¢
l
¢
EEPROM error
l
l
¢
¢
Communication error between IPDU (No abnormal stop)
t
l
l
l
G-Tr short-circuit protection
l
t
l
l
Detect circuit error
l
t
l
l
Current sensor error
l
l
t
l
Comp. lock error
t
l
t
l
Comp. break down
14
A
C
B
Board position Fig. 14
Legend:
A Position 4 LED Inverter
Diagnostics Board (KHP0040/42
only)
B Position LED GMC Diagnostics
Board
C Installation terminal strip
D800 O: Red
D801 O: Yellow
D802 O: Yellow
D803 O: Yellow
l
: Flashing
t
: Off
¢
: On
Summary of Contents for KHP0038
Page 2: ...22 ...
Page 21: ...21 Electrical connections 13 Legend DC low voltage AC ...
Page 33: ...33 Wiring Diagram Additional Systems Bi Valent Parallel System In line Electric Heater ...
Page 35: ...35 Wiring Diagram Additional Systems Bi Valent Retrofit System S Plan Boiler ...
Page 71: ...71 Spare Part List KHP0041 4kW KHP0038 6kW KHP0039 8kW ...
Page 73: ...73 Spare Part List KHP0040 12kW KHP0042 15kW ...
Page 83: ...83 Notes ...