AeroForce interceptor User Manual Download Page 7

 

entered indicating the number of scans that each 

Cyclic

 screen will be viewed.  

For data rates 1 or 2 figure about 5 scans per second, so 20 scans will result in 
each screen staying up for 4 seconds.  You may have to go back and adjust 
this value a second time after you get a feel for this value.  Different vehicles 
will respond at different speeds, and the data rate you choose will also effect 
this outcome.   If a screen is not configured, that screen will default to the 
factory setting of 

Intake Air Temp

. for its turn in the cycle. 

      Example:  Display 

knock retard

 and 

fuel pressure

 for 20 scans (~4 seconds), 

knock retard

 and 

ignition advance

 for 10 scans (~2 seconds), and 

intake air 

temp

. and 

oil pressure

 for 10 scans (~2 seconds).     

      Procedure:    Enter 

Cyclic Setup

.  In 

Screen 1

 

Field 1

 select 

knock retard

select “

Next

”, 

then

 

for

 “Screen 1 Field 2” 

select

 fuel pressure

, select 

Next

”, on “

Screen 2

 

Field 1

” select 

knock retard, 

 select “

Next

”, for 

Screen 2 Field 2

” select 

fuel pressure, 

hit

 “Next”, 

for “

Screen 3 Field 1

” 

select 

knock retard

, hit “

Next

”, for “

Screen 3 Field 2

” select 

ignition 

advance

, hit “

Next

”, for “

Screen 4 Field 1

” select 

intake air temp

, hit 

Next

”, for “

Screen 4 Field 2

” select 

oil pressure

, hit “

Next

”.  After leaving 

“S

creen 4 Field 2”

 you will then be asked to enter the number of scans for 

each screen, enter 10.  You will then go back to the main menu where you will 
select 

Cyclic Scan

”.   You’ll then enter a scan mode where the parameters 

you selected will cycle in their predetermined amounts of time.    You’ll need 

to experiment with the number of scans because scan rate, and the vehicle 
itself will effect how long each scan takes.  If the parameter list in 

Setup

 is 

changed, the 

Cyclic Setup

 must be completed again. 

e)  Cyclic Time

.  Choosing this will allow you to enter a number of scans (time) 

between screen (parameter) changes in 

cyclic scan

 mode.                                                                  

f)  RECORD.  

Upon selecting 

record

, you will initially be asked which mode to 

record in, normal 

Scan

 or 

Cyclic Scan

.  The unit will return to the selected 

scan mode except the first letter of each field description will be replaced with 
a square block to indicate that 

record

 is active.  You may notice that the 

gauge is scanning much faster in this mode.  Once the throttle position reaches 
50% or higher the unit will automatically start recording the displayed data for 
approximately 45-60+ seconds.  When recording begins, the display colors 
will invert as an alert.  The recorded file will be saved for replay until 

record

 

is selected again and the proper record conditions are met.  The new file will 
overwrite the old.  The 

Interceptor

 will maintain the file even when powered 

down.  If in 

record

 mode, you wish to return to normal 

scan

 mode, access the 

menu screen and select 

record

 again.  This will disable it until selected again 

via the menu.  Recording fuel economy will slow down the data rate as is not 
recommended if speed is important. 

g)  PLAY.  

Once 

Play

 is selected the 

Interceptor

 will return to the normal 

scan

    

screen but will show the first frame of a recorded log.  You will notice the 
field descriptions flickering to indicate playback mode is in effect.  Pushing 
the right button will toggle forward to the next frame in chronological order, 
the left button will toggle backwards, or to the very last frame if done at the 
beginning of the file.  Holding either button down will quickly scroll through 
the data until the button is released.  The backlight will flash every time a new 

Summary of Contents for interceptor

Page 1: ...by USER MANUAL FIRMWARE VERSION 2 0 www aeroforcetech com www aeroforcetech com Made in the USA Patent Pending...

Page 2: ...of the driver Aeroforce Technology Inc shall not be held liable in any way for any incidental or consequential damages to the vehicle driver passengers and or other involved parties or property occurr...

Page 3: ...e OBD2 connector do not plug in yet to the location of the Interceptor s The Interceptor will fit in any 2 1 16 or 52mm gauge pod or can be mounted in a custom fashion anywhere within 5 feet of the OB...

Page 4: ...sting circuit in the fuse block to power an add on accessory such as the Interceptor without the need to cut or splice any wires The use of this kit is highly recommended as most of the problems with...

Page 5: ...eters that will then be available for scan see Setup below in the Operation section for more details on this See page A1 of these instructions for the list of parameters supported by the Interceptor R...

Page 6: ...V8 s and Knock retard on Ford Mustangs except normally aspirated DOHC V8s such as the 1996 2001 Cobra and 2003 2004 Mach 1 You should consult the parameter lists by manufacturer in the appendix of th...

Page 7: ...n takes If the parameter list in Setup is changed the Cyclic Setup must be completed again e Cyclic Time Choosing this will allow you to enter a number of scans time between screen parameter changes i...

Page 8: ...o read in bright sunlight l DIMMER Selecting Dimmer will take you to a new screen with a brightness value displayed between 1 3 1 is the dimmest 3 the brightest Using the left button you can raise thi...

Page 9: ...utton and repeat until all 4 digits are correct After entering the last digit you will select above or below depending on if you want the warning light to activate above or below the set point you ent...

Page 10: ...Fuel Economy Selecting this will display the average calculated fuel economy since the last reset Average in only calculated when instantaneous fuel economy is displayed on the gauge v Fuel Economy Re...

Page 11: ...ser If both display fields are showing analog inputs the gauge may take up to 10 minutes to time out and turn off since it is not connected to the vehicle s data bus in this situation Non Volatile Mem...

Page 12: ...ce Technology is required on order to have warranty service performed Before sending an Interceptor back for warranty service you must obtain a Return Materials Authorization number from Aeroforce Tec...

Page 13: ...r in millivolts 22 OXYGEN SENSOR B2 O2 bank 2 sensor in millivolts 23 RUN TIME MINS engine run time is tenths of seconds since last engine start 24 BATTERY VOLTAGE Alternator battery output voltage 25...

Page 14: ...22 PULSE WIDTH 2 1998 4 6L injector 1 pulse width in counts 23 PULSE WIDTH 3 1996 1997 4 6L injector 1 pulse width in counts 24 PULSE WIDTH 4 2001 2004 Lightning injector 1 pulse width in counts 25 P...

Page 15: ...ong term fuel trim 16 OXYGEN SENSOR O2 bank 1 sensor in millivolts 17 FUEL LEVEL amount of fuel in the tank in gallons 18 CALCULATED EXHAUST GAS TEMP calculated by the PCM 19 TRANS TEMP Transmission T...

Page 16: ...on our web site at http www aeroforcetech com files Partial_list_of_diagnostic_trouble_codes txt http www aeroforcetech com files Partial_list_of_diagnostic_trouble_codes txt The web site www trouble...

Page 17: ...ely cold temperatures below 20 degrees F Therefore it is recommended to unplug the gauge before starting these cars in these extremely cold temperatures and plugging it back in a few seconds after the...

Page 18: ...lower faster than 3 Both can be set to 2 or higher slower Knowing this set the PRO gauge for parameters that require monitoring at a high data rate such as knock retard or ignition advance This way yo...

Reviews: