AeroFlow MAXI 2450 Manual Download Page 6

The is able to automatically 

switch AeroFlow® heater off in 

case of an open window will be 

detected. In this menu you can 

switch this function on or off. 

 

Enable or disable the open 

window detection. 

 

 

 

 

 

 

The AeroFlow® heater can be 

swichted into a holiday mode. 

In holiday mode, the program (if 

active) is disabled for the dura-

tion of the absence. 

 

 

Pomocí tlačítek se šipkami 

zadejte počet dní, během 

kterých nebudete přítomni. 

 

 

Use the arrow buttons to 

enter the number of days you 

are leaving. 

 

 

 

 

The return temperature is the 

temperature that should gov-

ern your return. 

When program is active 

(menu "Configuration" 

 Pro-

grams = ON), the return tem-

perature can not be selected. 

After reaching the return time 

the heating plan will be con-

tinued. If no time frame is ac-

tive (paused heating between 

two time frames), the An-

tifreeze temperature is ap-

plied. So the heating plan 

continues as programmed. 

 

    If program is disabled, you can 

use the arrow keys to set the 

return temperature. Confirm 

with OK. The status display 

with the suitcase icon and the 

number of remaining days off 

will appear. The absence tem-

perature corresponds to the 

Antifreeze temperature. To 

change the temperature for 

your absence, press an arrow 

key in the status display. The 

Temperature-overview display 

appears. Change the absence 

temperature with the arrow 

keys and confirm with OK. To 

deactivate the holiday mode 

set "days absent" to "-" (not 

"0"). During holiday mode you 

can change the Antifreeze 

temperature in the Antifreeze 

menu, but this will not be ap-

plied for the current absence. 

 

 

 

 

 

 

 

 

 

 

 

 

Select the current weekday 

and confirm with OK. 

 

 

www.zatopte.si

6

Open window detecon

Detecon OFF

Holidays

OFF

D

a

ys o

u

t

Return me

09:00

Požadovaná teplota
při návratu

15.0°C

Set the me

Select day

Monday

Summary of Contents for MAXI 2450

Page 1: ...ontrol must always be performed using a suitable room thermostat 3 Installation Our devices are mounted horizontally on the wall Attach ment to the ceiling is not permitted The radiator should normall...

Page 2: ...transport misuse connection to incorrect mains voltages failure to observe the appropriate operating instructions or installa tion instructions improper cleaning or corrosion damage due to caustic wat...

Page 3: ...2 405 MAXI 2450 1066 405 COMPACT 1300 466 405 SLIM 1200 766 120 MIDI 1950 766 405 SLIM 1600 1066 120 SLIM TALL 1600 232 1040 For the assembly please perform the following steps 1 The two U rails must...

Page 4: ...low heater is tem porarily switched off Holiday Mode The digit below the icon indicates the number of remaining holidays see page 12 Keylock Childlock ON to enable disable press both arrow buttons sim...

Page 5: ...e boost function if you want to increase the room temperature quickly Press OK to activatethe boost function Thedefaultsettingis30 00minutes anditwillstartimmediately Youdo not need to press any furth...

Page 6: ...between two time frames the An tifreeze temperature is ap plied So the heating plan continues as programmed If program is disabled you can use the arrow keys to set the return temperature Confirm with...

Page 7: ...n time frame 1 and time frame 2 7 01 a m to 7 59 a m the Antifreeze protec tion temperature is retained Select a Antifreeze tempera ture between 0 C and 17 C Confirm with OK The frost protection tempe...

Page 8: ...ou zdrav ho klimatu v m stnosti a sporn ho vyt p n Na e dlouholet pr ce na v voji a modern v robn postupy jsou p edpokladem pro dlouhou ivotnost a vysokou tr valou hodnotu Va eho produktu AeroFlow 30l...

Page 9: ...barkeit des Grundger tes Mit dem Erwerb dieses Ger tes haben Sie sich f r ein innovatives Qualit tsprodukt der absoluten Spitzenklasse entschieden Wir bedanken uns f r Ihr Vertrauen Die AeroFlow Produ...

Reviews: