General Information
1. Safety instructions
information listed here carefully. Store these instructions in
a safe place and pass them on to the following user/owner if
necessary. The electronic heating you have just purchased is
only suitable for heating inside enclosed rooms. Damaged
devices (e.g. damaged connecting cables) must not be op-
erated.
Our radiators are tested according to the applicable IP pro-
tection class when properly installed (International Protec-
tion Code – in this case: Protected against spray water). In the
fixed electrical installation, a separating device with at least
a 3mm contact opening shall be provided on each pole (for
example, a safety device, residual current circuit breaker).
Substances which are prone to ignition or thermal decom-
position (e.g., adhesives of floor coverings) may only be used
if it is certain the heater has been cooled to room tempera-
ture. The heater must not be placed directly below a wall
socket.
The radiator is not intended to be used by persons (including
children) with limited perceptual abilities or by people with
lack of experience and / or lack of knowledge of using it. Un-
less they are supervised by a person responsible for their
safety or have received instructions from this person on how
to use the radiator. Children should be supervised to ensure
that they do not play with the radiator.
2. Electrical connection
Your AeroFlow® electric radiator system is suitable for fixed
connection to wall sockets or operation from power sock-
ets. An electrician must be consulted when installing it via
a wall socket. If the mains connection cable of the radiator
is damaged, it needs to be replaced by us or a suitably qual-
ified electrician in order to prevent danger and additional
damage.
The radiator may only be operated with a thermostat di-
rectly on the radiator or with an external control. The heat-
ing control must always be performed using a suitable
room thermostat.
3. Installation
Our devices are mounted horizontally on the wall. Attach-
ment to the ceiling is not permitted. The radiator should
normally be installed under a window or on an external
wall. Please ensure that the radiator can radiate into the
room as freely as possible. You can find our detailed instal-
lation information on Page 7.
4. Heating
thermostat. A higher setting means a longer operating time
on the radiator. Please refer to the operating instructions of
the room thermostat on the following pages. It is possible
that a slight odour can develop during initial commission-
ing, since some materials still have to be baked out. This
does not pose any threat, and it will run off completely after
a period of time. Please ventilate the rooms well if neces-
sary. In rare cases, noise can occur in the form of cracking,
which is caused by heat-induced material movements,
which are harmless.
5. Overheating protection
For your safety, the heater is equipped with a temperature
switch integrated in the heating system. If the radiator is
not heated in the permitted manner (e.g. by covering or
blocking) the radiator switches off automatically. The cov-
ering of the heater (e.g. through towels) during operation
is not permissible, it is a fire hazard! Any resulting defects
on a temperature switch and the resulting costs for the re-
pair shall be borne exclusively by the party causing the
damage. We can offer you a towel rack suitable for our ra-
diators in our online shop.
6. Malfunctions
If the radiator does not emit any heat, please check that the
thermostat is preset to the desired temperature. In addition,
it is essential to check that the local power distribution is
switched on or that the fuse is in working order. If you en-
counter such malfunctions, please contact your installer. In
the event of a complaint being addressed to us, the serial
number of the device is required for order processing. You
will find this information on the rating plate.
www.zatopte.si
1
AeroFlow®
FlexiSmart
Heating panel