Use

The “Mode button” allows you to select the different operating modes:      
     Comfort,     Economy,      Frost protection, programming

 AUTO

 mode.

Pressing the 

i

 button gives you the temperature of the room

 

or the set-point 

temperature, according to your configuration

 

settings in menu 5.

If the ON icon is displayed, this means that the device is in heating demand mode.

Time Setting

In Off mode, press the      button.

The days flash.

Press the      button once to access the 
programming, and press the On/Off button 
once to exit the setting mode.

Menu number

19,0

PROG

c

On-Off

Button

>10sec.

OK

1
2
3
4
5
6
7

3,5

c

OK

1
2
3
4
5
6
7

----

OK

1
2
3
4
5
6
7

0,0

c

OK

1
2
3
4
5
6
7

90

OK

1
2
3
4
5
6
7

0

OK

1
2
3
4
5
6
7

42

Instruction digital thermostat (ITRD)

Hours

Minutes

Day

On-Off

Button

OK

00:00

1
2
3
4
5
6
7

19,0

PROG

On-Off

Symbol off

c

Button

On-Off

Mode button

15,5

c

i

15,5

c

i

19,0

c

i

Configuration

When in Off mode, press and hold down the On/Off 
button for 10 seconds to access the first configuration 
menu.

If the Heater is in mode „Off”, the display shows

Digital control display

Menu 1:ECO set-point adjustment

By default, Economy setting = Comfort setting - 3.5°C. This 
reduction can be set between 0 to -10°C, in steps of 0.5°C.
 
To adjust the reduction, press on the + or - buttons then press 
OK to confirm and go to the next setting.

To allow the user to modify the set-point, press on the + button 
in Economy mode until “----” is displayed on the screen.

Menu 2: Correction of the measured temperature

If there is a difference between the temperature noted
(thermometer) and the temperature measured 
and displayed by the unit, menu 2 acts on the measurement 
of the probe so as to compensate for this 
difference (from -5°C to +5°C in steps of 0.1°C).

To modify, press on the + or - buttons then press
OK to confirm and go to the next setting.

Menu 3: Backlight time out setting

The time out can be adjusted between 0 and 225 seconds, 
in steps of 15 seconds (set on 90 seconds by default).

To modify, press on the + or - buttons then
press OK to confirm and go to the next setting.

Menu 4: AUTO mode temperature display option

0 = Continuous display of room temperature.

1 = Continuous display of set-point 

temperature.

To modify, press on the + or - buttons then
press OK to confirm and go to the next setting.

Menu 5: Product number

This menu allows you to view the product number.

To exit the configuration mode, press OK.

Programming

When starting up, the “Comfort mode from 8am to 
10pm” program is applied to all the days of the week.

To change the programming, press the

 PROG

 button in 

Off or AUTO mode. The 1st time slot flashes on and off.

no 

 “Frost protection” 

stroke

Confirm and go to
the next day

Frost protection
mode for 1 hour

Day

OK

22 24

1
2
3
4
5
6
7

20

16 18

00:00

14

10 12

8

PROG

Economy mode for 1 hour

4

6

PROG

2

0h

Comfort
mode for 1 hour

Control display

two strokes
“Comfort” 

one 

 

“Economy” 

stroke

Quick programming:
To apply the same program to the following day, press and hold the OK button for 
approximately 3 seconds until the program of the following day is displayed. To exit 
the programming mode, press on the On/Off button.

Continuous Comfort

Pressing and holding the + or - buttons lets you

 

change the 

current set-point (+5 to

 

+30°C) in

 

steps of 0.5°C.

Continuous Economy mode

The Economy set-point is indexed according to the Comfort 
set-point. The reduction can be modified in the configuration 
settings for menu 1.

Modifying the Economy set-point

The set-point can be modified if it was authorized in the 
configuration settings in menu 1 (“----”).

Pressing and holding the + or - buttons lets you change the 
current set-point (+5 to +30°C) in steps of 0.5°C.

6

QUICK ACCESS see page 7!

Summary of Contents for COMPACT 1000 TFLH-2

Page 1: ...W RME WENN S DRAUF ANKOMMT MADE IN GERMANY Bedienungsanleitung AeroFlow Heizung S 1 4 User manual AeroFlow Heater S 5 8 Manuel AeroFlow chauffage S 9 12 by Thermotec GmbH...

Page 2: ...eizger t ist f r den Festanschluss an eine Wandanschlussdose vorgesehen und muss vom Fachmann installiert werden Die Regelung muss zwingend ber einen geeigneten Raumthermostaten erfolgen Siehe Schaltb...

Page 3: ...2 3 4 5 6 7 0 0c OK 1 2 3 4 5 6 7 90 OK 1 2 3 4 5 6 7 0 OK 1 2 3 4 5 6 7 42 Grundeinstellung Anleitung Displayregler ITRD Uhrzeit einstellen In Betriebsart AUS Taste dr cken Die Tagesanzeige blinkt W...

Page 4: ...best tigen Sie mit OK Zum L schen der befristeten Temperatureinstellung dr cken Sie die Taste OK erneut Abwesenheitsfunktion Durch Dr cken der Taste k nnen Sie Ihr Ger t f r die Dauer von 1 bis 365 Ta...

Page 5: ...Ein Aus Schalter Schnelles Blinken Impulsgeber Zum Umschalten der Modi Taste kurz dr cken Bringen Sie den Sender in den Konfigurationsmodus Siehe Bedienungsanleitung Sender berpr fen Sie dass die Kon...

Page 6: ...xings are for fixing to solid masonry walls seek advise for other wall types For positioning of the drill holes for the wall brackets see installation drawing Only the enclosed wall brackets should be...

Page 7: ...modify press on the or buttons then press OK to confirm and go to the next setting Menu 3 Backlight time out setting The time out can be adjusted between 0 and 225 seconds in steps of 15 seconds set o...

Page 8: ...TRUCTIONS FOR USE WITH The first page of the instructions packed with the radiator show factory pre set positions which for general use can be ignored at this stage QUICK ACCESS Time setting In OFF mo...

Page 9: ...transmitter guide Check that the receiver s LED is no longer Flashing Application example with a door window magnetic contact When associated with the receiver the magnetic contact can in control sys...

Page 10: ...vous entendiez quelques bruits de craquements la premi re utilisation ceci est normal et correspond la dilatation du mat riel 5 protection contre la surchauffe Pour votre s curit le chauffage est qui...

Page 11: ...s par d faut Pour modifier appuyez sur les touches ou puis appuyez sur la touche OK pour valider et passer au r glage suivant Menu 4 Choix de l affichage de la temp rature en mode AUTO 0 Affichage per...

Page 12: ...pas de 0 5 C Mode AUTOMATIQUE Dans ce mode l appareil suit la programmation Un appui sur la touche PROG permet de modifier la programmation Mode Sablier Un appui sur la touche permet de r gler une tem...

Page 13: ...ment rapide mode impulsionnel Pour passer d un clignotement l autre appuyez bri vement sur la touche du r cepteur Sur l metteur envoyez l information radio d association voir sa notice V rifiez que le...

Page 14: ...13...

Page 15: ...14...

Page 16: ...Garantie Zertifikat MADE IN GERMANY warranty certificate MADE IN GERMANY Hersteller Thermotec GmbH Hauptstra e 30 02899 Sch nau Berzdorf WARRANTY ZERTIFIKAT...

Reviews: