
AEO TECHNOLOGY www.aeorc.com
Entire Contents © Copyright 2010
2
"T: 000" will be changed to be "P: 00" after pressing button B. It means the pairs of the magnets in the motor.
.
3. Connection
Type
Connection Type for K2 working on the voltage over 5.5V
:
Connection Type for K2 working on the voltage below 5.5V (1 cell Lipo):
4. Application
Method
1. Make sure the correct connection
2. Measure KV
Turn the knob and make the PPM signal output be the max(T:100).
3. Measure RPM and frequency(Hz)
Turn the knob and set the PPM signal output.
4. “Hold “the max
If you want to hold the max data of KV, rpm and frequency, just need to keep pressing button A for 1-2
seconds until "H" being displayed in the screen.
5. Attentions
:
1. Because of the peculiarity of LCD panel when working in cryogenic environment, it is a normal phenomenon
that the refresh rate will be dropped off.
2. Please power off after the measuring.
3. The KV meter is used for testing rpm/KV for BL motors.
4. The motor should be no-loading, and top throttle is required when measuring KV.
5. There may be some error for a very few micro motors with very low magnetism magnets.
6. For some high KV motors, long time no-loading working is not suggested.