CLEANING & MAINTENANCE

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit 
with the dusting brush attachment.The motor is permanently lubricated and never needs oiling. If the motor bearings are 
making excessive or unusual noises, replace the motor with the exact service motor. The impeller should also be replaced.

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service discon-

necting means to prevent power from being switching on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent warning device, such as a tag, to 
the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all 

applicable codes and standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) 

of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s 
guideline and safety standards such as those published by the National Fire Protection Associa-
tion (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning   Engineers 
(ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden 

utilities. 

f ). Ducted fans must always be vented to the outdoors. 
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Inter-

rupter) - protected branch circuit (ceiling installation only). 

h). This unit must be grounded. 
 i). Not for Use in Kitchens.
 j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside - Do not vent exhaust 

air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any 

Solid-State Speed Control Device.

 l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. 
    DO NOT MOUNT THIS PRODUCT IN A WALL. 
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off 

power unit. 

4. Please read specification label on product for further information and requirements.

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:

VENTILATION FAN

MODEL: 

 www.aeropurefans.com

AP200D-S
AP200DH-S

Cod: 0060302694-A

Summary of Contents for AP200D-S

Page 1: ...e Protection Associa tion NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit In...

Page 2: ... fan continuously responds to changing environmental conditions H means humidity adjustment may be required This figure is factory set for about 80 Ambient temperature of 25 SENSITIVITY ADJUSTMENT The H has been factory set for most shower applications However if the fan is in a tub area or is being used for dampness control the H may need to be increased toward maximum If the control is respondin...

Page 3: ... Refer to the wiring diagram and connect the wires as shown ASSEMBLY INSTRUCTIONS 3 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not included Using tape not included secure all the ductwork connections so that they are air tight The ducting from this fan to the outside of building has a strong effect on the a...

Page 4: ...e in normal household use for a period of 72 months THIS WARRANTY DOES NOT COVER Damages from improper installation Damages from shipping Damages from misuse abuse accident alteration lack of proper care and maintenance Damages from service by persons other than a licensed electrician Does not cover any labor or transportation charges related to the repair of this product This warranty does not ex...

Page 5: ...tilateurs doivent toujours être évacués vers l extérieur g Peut être utilisé au dessus d une baignoire ou d une douche lorsqu elle est branchée à un DDFT disjoncteur détecteur de fuite à la terre circuit de dérivation protégé installation de plafond uniquement h Cet appareil doit être mis à la terre i Ne doit pas être utilisé dans la cuisine j Pour réduire les risques d incendie et pour évacuer l ...

Page 6: ...e ambiant de 25 L AJUSTEMENT POUR LE SENSITIVITÉ Le H humidité senseur et fixé par l usine pour le plupart de douche bain applications typiques Si le ventilateur est dans une douche ou une baignoire ou être utilisé pour contrôler l humidité le H humidité senseur doit être augmenter à maximum Si le senseur d humid ité répond plus souvent aux conditions dans l environnement qui changent il faut rédu...

Page 7: ...ement des raccords homologués par UL pour relier le circuit électrique de votre maison à la plaque de câblage Branchez les fils comme illustré ci dessous BLK BLK VENT WHT WHT GRD GRD BOÎTIER DE COMMUTATEUR UNITÉ ENTRÉE COMMUTATEUR MISE À TERRE GRD NOIR BLK BLANC WHT PANNEAU DE CONNEXION BOÎTIER DE COMMUTATEUR UNITÉ ALIMENTATION 120V CA RÉCEPTACLE COMMUTATEUR INSTALLATION DE LA GRILLE NOIR BLK NOIR...

Page 8: ...eux dans un usage domestique normal pour une période de 72 mois CETTE GARANTIE NE COUVRE PAS Les dommages causés par une mauvaise installation Les dommages causés par l expédition Les dommages causés par un usage abusif accident modification manque de soins appropriés et l entretien Les dommages causés par un service par des personnes autres qu un électricien agréé Ne couvre pas les frais de main ...

Page 9: ...tadounidense de Ingenieros de Calefacción Refrigeración y Aire Acondi cionado ASHRAE por sus siglas en inglés y los códigos locales vigentes e Al cortar o taladrar en paredes o techos no dañe el cableado eléctrico y otros servicios ocultos f Los ventiladores de conductos siempre deben orientarse hacia el exterior g Aceptable para su uso sobre una bañera o ducha cuando se conecta a un circuito deri...

Page 10: ... fábrica en aproximadamente un 80 temperatura ambiente de 25 C AJUSTE DE SENSIBILIDAD La H se ha configurado de fábrica para la mayoría de las aplicaciones en duchas Sin embargo si el ventilador está en el área de la bañera o se utiliza para controlar la humedad puede ser necesario aumentar la H hacia el máximo Si el control actúa con demasiada frecuencia a las condiciones ambientales cambiantes p...

Page 11: ...REDONDO Conecte el conducto redondo no incluido al conector de la compuerta conducto y lleve el conduc to hasta la cubierta de techo o pared no incluida Usando cinta no incluida asegure todas las conexiones de los conductos para que sean herméticas El conducto de este ventilador al exterior del edificio tiene un gran efecto en el flujo de aire el ruido y el uso de energía del ventilador Utilice la...

Page 12: ...efectuosa en el uso doméstico normal por un período de 72 meses ESTA GARANTÍA NO CUBRE Daños por instalación incorrecta Daños por el transporte Daños por mal uso abuso accidente alteración falta de cuidado y mantenimiento adecuados Daños causados por la asistencia de personas que no sean electricistas autorizados No cubre los gastos de mano de obra o transporte relacionados con la reparación de es...

Reviews: