AERMEC Omnia UL 16 N Use And Installation  Manual Download Page 1

 Omnia UL 

16 N

 Omnia UL 

21 N

 Omnia UL 

36 N

M A N U A L E   D ’ U S O   E   I N S T A L L A Z I O N E
U S E   A N D   I N S T A L L A T I O N   M A N U A L
M A N U E L   D ’ U T I L I S AT I O N   E T   D ’ I N S TA L L AT I O N
B E D I E N U N G S

ͳ

  U N D  I N STA L L AT I O N SA N L E I T U N G

M A N UA L  D E  I N S T R U C C I O N E S  E  I N S TA L A C I Ó N

VENTILCONVETTORE CON MOTORE BRUSHLESS INVERTER 

Έ

EC

Ή

 PER INSTALLAZIONE A PAVIMENTO CON TER

ͳ

MOSTATO ELETTRONICO E DEPURATORE PLASMACLUSTER®, PER USO RESIDENZIALE 

FAN COIL UNIT WITH INVERTER BRUSHLESS MOTOR 

Έ

EC

Ή

 FOR FLOOR INSTALLATION WITH ELECTRONIC 

THERMOSTAT AND PURIFIER PLASMACLUSTER®, FOR RESIDENTIAL USE

UNITÉ DE VENTILO

ͳ

CONVECTEURS AVEC MOTEUR VARIATEUR BRUSHLESS 

Έ

CE

Ή

 POUR L'INSTALLATION 

AU SOL AVEC THERMOSTAT ÉLECTRONIQUE ET PURIFICATEUR PLASMACLUSTER®, À USAGE 
D'HABITATION

FAN

ͳ

COIL

ͳ

EINHEIT MIT INVERTERBÜRSTENLOSEN MOTOR 

Έ

EG

Ή

 FÜR VERLEGUNG MIT ELEKTRONISCHEM 

THERMOSTAT UND REINIGER PLASMACLUSTER®, FÜR WOHNZWECKE

UNIDAD DE BOBINA DE VENTILADOR CON MOTOR INVERSOR SIN ESCOBILLAS 

Έ

CE

Ή

 PARA LA INSTALA

ͳ

CIÓN DEL PISO CON TERMOSTATO ELECTRÓNICO Y PLASMACLUSTER® PURIFICADOR, PARA USO RESI

ͳ

DENCIAL

IULIPCLJ 1201 - 6976445_00

Omnia ULI_PC

Summary of Contents for Omnia UL 16 N

Page 1: ...RUSHLESS MOTOR ΈECΉ FOR FLOOR INSTALLATION WITH ELECTRONIC THERMOSTAT AND PURIFIER PLASMACLUSTER FOR RESIDENTIAL USE UNITÉ DE VENTILOͳCONVECTEURS AVEC MOTEUR VARIATEUR BRUSHLESS ΈCEΉ POUR L INSTALLATION AU SOL AVEC THERMOSTAT ÉLECTRONIQUE ET PURIFICATEUR PLASMACLUSTER À USAGE D HABITATION FANͳCOILͳEINHEIT MIT INVERTERBÜRSTENLOSEN MOTOR ΈEGΉ FÜR VERLEGUNG MIT ELEKTRONISCHEM THERMOSTAT UND REINIGER ...

Page 2: ... aux position 14 light visualisations uli_pc in the standard configuration 14 functioning characteristics 15 packaging 15 unit installation 15 electrical wirings 16 rotating the coil 16 dip switch configuration 17 important information and maintenance 17 operating limits 18 INDICE TABLE OF CONTENTS INDEX INHALTSVERZEICHN ÍNDICE ...

Page 3: ...rip tray and fan volute ensure thorough clean ing of the unit by specifically trained personnel essential for installations in venues subject to crowding or in those with spe cial hygiene requirements The new centrifugal fan unit is so quiet that at a normal oper ating speed you cannot hear when the OMNIA ULI_PC cuts in The use of the electronic control panels avoids the annoying noise typical of ...

Page 4: ...nked with the type of accessory connected to the thermostat VENTILATION LOGIC IN AUX POSITION SYSTEM VENTILATION DESCRIPTION 2 pipe system Auto VenƟlaƟon funcƟons with the thresholds of Auto mode except in pre venƟlaƟon post venƟlaƟon 2 Pipe System with Plasma Cluster V1 VenƟlaƟon acƟve at minimum speed for environment puriĮcaƟon 2 Pipe System with Bactericide lamp V1 VenƟlaƟon acƟve at minimum sp...

Page 5: ...rom a minimum of 0 00 to a maximum of 2 40 Frost Protection anti freeze protection The anti freeze protection allows you to check that the room tem perature never falls to freezing values even when the fan coil is switched off and the selector A is OFF In the event that the temperature falls below 7 C the thermostat starts up the fan coil in Heat mode with a setting of 12 C and ven tilation in AUT...

Page 6: ...e Continuity of the protection wires The electrical circuits are connected to the 230V mains voltage all the connections and components must therefore be corre spondingly insulated for this voltage CHARACTERISTICS OF THE CONNECTION CABLES Use H05V K or N07V K type cables with 300 500V with insula tion piped or ducted Use power supply cables with a minimum cross section of 1 mm2 All the cables must...

Page 7: ...ter on the outer or inner surfaces of the fan coil this might cause short circuits CLEAN THE FILTER PERIODICALLY Cleaning the filter frequently guarantees enhanced operating efficiency Check whether the filter is very dirty in this case clean it more often Clean frequently remove the dust that has built up using a vac uum cleaner and the use of water and cleaning substances con siderably speeds up...

Page 8: ...emperature of the air in the room with wet bulb C 15 3 3 3 3 3 3 17 3 3 3 3 3 3 19 3 3 3 3 3 3 21 6 5 4 3 3 3 23 8 7 6 5 5 OPERATING ENVIRONMENT ALREADY TRANSLATED OPERATING ENVIRONMENT The units are designed for installaƟon in closed environments in condiƟons of urban non marine atmosphere with non corrosive and non dusty characterisƟcs Under no circumstances the following concentraƟons of pollut...

Page 9: ...ura esterna dell apparec chio Condensation on the unit cabi net Phénomènes de condensation sur la structure exterieure de l appareil Kondenswasserbildung am Gerät Fenómenos de condensación en la estructura externa del aparato SOLUZIONE REMEDY SOLUTION ABHILFE SOLUCIÓN Sceglierelavelocitàcorrettasulpannellocomandi Select the speed on the control panel Choisir la vitesse sur la panneau de commandes ...

Reviews: