ANL
are identified by the following:
−
PACKAGING LABEL: that includes the pro-
duct identification data.
−
TECHNICAL PLATE: placed on the right strut
side. (see TaV.1)
NOTE:
If the identification plate, or any other means
to identify the product, is tampered with, re
-
moved or missing, installation and maintenan
-
ce operations are hampered.
Standards and Directives respected on desi
-
gning and constructing the unit:
ProteCtIoN rAtINg
1.
IP 24
ACOUSTIC PArT:
1.
ISO DIS 9614/2
(inTEnsimETriC mETHod))
2.
soUnd poWEr (En iso 9614-2)
3.
SOUND PRESSURE
(En iso 3744)
rEFrIGErAnT GAS:
This unit contains fluoride gases with green
-
house effect covered by the Kyoto Protocol.
Maintenance and disposal must only be
performed by qualified staff.
STAnDArD:
UL 1995
Heating and cooling equipment.
ANSI/NFPA
standard 70 national Electrical code (n.E.C.).
CSA C.22.1.- C.22.2
Safety Standard Electrical Installation.
1.
DeSCrIPtIoN AND CHoCe oF UNIt
3.
CECK LIST
2.
ProDUCt IDeNtIFICAtIoN
TECHNICAL
PLATE
TAV.1
Chillers and heat pumps for outdoor condensed in
the air with R410A Series ANL have been designed
and manufactured to satisfy heating and cooling
needs and the production of domestic hot water
(dHW) in medium to small commercial or residential
buildings.
These units, have extremely silent functioning and
are highly efficient and reliable, thanks to the use of
exchangers with a large exchange surface and low-
noise high-efficiency scroll compressors.
They are available in the following versions:
ANL "°" Standard
ANL "H" Heat pumps
The versions can be in different set-ups at the same
time in order to satisfy a wide range of plant engine-
ering solutions:
"°" Standard
"P" Pumps
"a" pump |storage tank
Hydraulic circuit
Version "°"
ANL100
ANL150
Water filter
Standard
Standard
Differential pressure switch
Standard
Standard
Flow switch
No
No
Safety valve
No
No
Air vent
Standard
Standard
Expansion tank
No
No
Hydraulic circuit
Version "P"
100
150
Water filter
Standard
Standard
Differential pressure switch
Standard
Standard
Flow switch
No
No
Safety valve
Standard
Standard
Air vent
Standard
Standard
Pump
Standard
Standard
Expansion tank
Standard
Standard
Hydraulic circuit
Version "A"
100
150
Water filter
Standard
Standard
Differential pressure switch
Standard
Standard
Flow switch
No
No
Safety valve
Standard
Standard
Air vent
Standard
Standard
Pump
Standard
Standard
Expansion tank
Standard
Standard
Storge tank
Standard
Standard
Chiller circuit
Scroll compressor
Standard
Water side heat exchanger
Standard
Source side heat exchanger
Standard
Dehydrator filter
Standard
Thermostatic valve
Standard
Solenoid valve
Standard
By-pass valve of hot gas injecton
No
Indicator for liquid passage
Standard
4-way cycle reverse valve
Standard
One way valves
Standard
Liquid storage tank
Standard
High pressure switch
Standard
Low pressure switch
No
High pressure transducer
Standard
Low pressure transducer
Standard
Desuperheater
No
Tap the liquid and discharge
No
Summary of Contents for ANL 100HA
Page 2: ......
Page 5: ......
Page 30: ...eN 1205 6755517_02 30 23 HYDrAULIC CoNNeCtIoNS 102 mm 4 0 in 413 mm 16 3 in IN 1 OUT 1 ...