AERMEC ANL 100-150HA Installation Manual Download Page 18

18

13.  SOUND DATA

Sound power

Aermec determines sound power values in 

agreement with the 9614 Standard, in com-

pliance  with  that  requested  by  Eurovent 

certification.

Sound Pressure

Sound pressure measured in free field con-

ditions  with  reflective  surface  (directivity 

factor Q=2) at 10mt distance from external 

surface of unit, in compliance with ISO 3744 

regulations.

KEY

- Water input temperature 

  

12 °C / 54 °F

- Temperature of  produced water             7 °C / 45 °F

- External air temperature  

  

35 °C / 95 °F

ANL

Total sound levels

Octave band [Hz] 

Pow.

dB(A)

Pressure.

125

250

500

1000

2000

4000

8000

dB(A)

10 m/33 ft.

dB(A)

1 m/3 ft.

Sound power for centre of band [dB] frequency

100

76.0

44.0

58.0

61.2

66.0

71.4

72.0

68.9

60.5

48.6

150

77.0

45.0

59.0

62.4

67.3

72.2

72.7

69.7

61.5

49.6

14.  PARAMETER CALIBRATION 

OF SAFETY AND CONTROL

CONTROL PARAMETERS

ANL

min.

standard

max.

Cooling set point

°C/°F

4

7

18

Heating set point

°C/°F

35

45

50

Defrosting mode

°C/°F

-9

3

4

Total differential

°C/°F

3

5

10

Autostart

auto

CALIBRATION  THERMOMAGNETIC  ANL60HZ

Models 60Hz

Compressors magnet 

circuit breakers

Pumps magnet 

circuit breakers

Fan magnet 

circuit breakers

ANL100HA 220V

19,0 A 

3,5 A 

Fixed 6A (also for auxiliary)

ANL100HA 460V

10,0 A 

1,8 A 

Fixed 6A (also for auxiliary)

ANL150HA 220V

23,0 A 

5,7 A 

Fixed 6A (also for auxiliary)

ANL150HA 460V

12,5 A 

3,0 A 

Fixed 6A (also for auxiliary)

100H

150H

SAFETY AND CONTROL COMPONENTS ELECTRIC DATA

High pressure pressure switch 

bar / psi

42 / 609

42

Low pressure pressure switch 

cold

bar / psi

4

4

PdC

bar / psi

2

2

High pressure transducer

bar / psi

40

40

/ 39
/ 95
/ 16
/ 37

/ 45
/ 113
/ 37
/ 41

/ 64
/ 122
/ 39
/ 50

/ 58

/ 29

/ 580

/ 609

/ 58

/ 29

/ 580

Summary of Contents for ANL 100-150HA

Page 1: ...IANL60HzPY 1007 6755517_00 CHILLERS AND HEAT PUMPS Technical Installation manual HEAT PU UM M ANL 100 150HA 60Hz SCROLL AXIAL M ODUCONTRO L EN ...

Page 2: ......

Page 3: ...xperience and in depth engineering research and it is built using top quality materials and advanced technologies In addition the CE mark guarantees that our appliances fully comply with the requirements of the European Machinery Directive in terms of safety We constantly monitor the quality level of our products and as a result they are synonymous with Safety Quality and Reliability Product data ...

Page 4: ... for heating pump 12 8 3 Project data 12 9 Performance in cooling mode 13 9 1 ANL 100 13 9 2 ANL 150 13 10 Performance in heating mode 14 10 1 ANL 100 H 14 10 2 ANL 150 H 14 11 Ethylene glycol solutions 15 11 1 How to interpret glycol curves 15 11 2 Static pressures useful to the system 16 12 Storage tank 17 12 1 Minimum maximum content of system water 17 12 2 Expansion vessel calibration 17 13 So...

Page 5: ...industrial environments EN378 Refrigerating system and heat pumps Safety and environmental require ments EN12735 Copper and copper alloys Seamless round copper tubes for air conditio ning and refrigeration UNI 12735 Seamless round copper tubes for air conditioning and refrigeration UNI 14276 Pressure equipment for cooling systems and heat pumps Therefore complying with the essential requisites of ...

Page 6: ...scaf folding or other elevation systems that may become necessary for carrying out servicing under war ranty Do not modify or tamper with the chiller as dangerous situations can be created and the manufacturer will not be liable for any damage caused The validity of the warranty shall be void in the event of failure to comply with the above mentio ned indications ANL are identified by the followin...

Page 7: ... cy scroll compressors They are available in the following versions HEAT PUMP ANL H Winter to summer switch over functioning can be applied via the cooling circuits Possibility of producing DHW DCPX mandatory STORAGE AND PUMP NOTES Refer to the configurator for the set ups that are not possible WARNING Before use or after a prolonged period of suspension of units with low air temperature functioni...

Page 8: ... H Heat Pump 8 VERSION A with storage tank and pump 9 HEAT RECOVERY without heat recovery units 10 COILS in aluminium 11 FIELD OF USE temperature of water produced up to 4 C 39 F 12 EVAPORATOR standard by PED 13 SUPPLY 6 3 220 60Hz 7 3 460 60Hz Example of configurator ANL100HA 6 4 CONFIGURATOR ...

Page 9: ...d plate exchanger withholding excess liquid during winter functioning 5 2 FRAME AND FANS Ventilation unit Helical type balanced statically and dynamically Electric fans are pro tected electrically by magnet circuit breakers and mechanically by anti intrusion metal grids according to IEC EN 60335 2 40 Standard Support frame Made in hot galvanised sheet steel with suitable thickness and painted with...

Page 10: ...utlet temperature at value set Self adapting differential switch guarantees minimum func tioning times of the compressor in systems with low water content Intelligent defrosting for pressure reduction allows to determine when the coil is effectively defrosted avoiding useless defrosting Hot gas injection defrosting In this way the machine consumes less energy increases heating capacity keeps effic...

Page 11: ...PLATES Quantity n 1 1 CHARGE Gas refrigerant R410A Kg lbs 12 7 27 99 16 0 35 27 Oil compressor 2x1 6 2x3 53 2x1 6 2x3 53 CIRCULATION PUMP Input power kW 0 75 1 5 Input current 220 3 60 Hz A 3 6 6 2 460 3 60 Hz 1 7 3 0 Useful head 1 kPa ft h 92 31 120 40 STORAGE TANK Water storage tank l gal 100 26 41 100 26 41 HYDRAULIC CONNECTIONS Inlet for water circulation Ø 1 1 Outlet for water circulation Ø 1...

Page 12: ... 0 5 0 1 5 1 0 2 5 2 0 3 5 3 50 122 50 122 45 113 Temperature of water produced C F External air temperature b s C F CONTACT AERMEC 10 5 15 0 5 10 15 20 25 30 35 40 46 15 16 17 18 4 5 6 7 8 9 0 1 1 1 2 1 3 1 4 1 46 115 46 115 40 104 Temperature of water produced C F External air temperature C F STANDARD MODE WITH DCPX MODE 8 OPERATING LIMITS 8 1 COOLING MODE 8 2 HEATING MODE FOR HEATING PUMP 8 3 P...

Page 13: ...76 29 2 8 54 27 3 9 18 14 36 3 6 12 34 3 6 94 32 2 7 81 30 2 8 58 28 2 9 22 16 37 4 6 16 35 4 6 98 33 3 7 85 31 2 8 63 29 1 9 27 18 38 5 6 21 36 4 7 08 34 3 7 94 32 2 8 67 30 1 9 36 Temp of water produced C F External air temeperature Pc Pe Pc Pe Pc Pe Pc Pe Pc Pe Pc Pe With thermosta tic valve Standard 4 37 6 6 90 35 5 7 88 33 3 8 91 31 1 9 84 28 9 10 65 26 8 11 25 6 39 1 6 90 36 9 7 93 34 7 8 97...

Page 14: ... Pe 57 11 8 62 54 25 8 62 55 64 9 31 51 67 8 57 52 93 9 31 22 58 10 05 49 32 8 62 50 47 9 31 23 71 10 05 23 15 11 26 47 17 8 62 48 22 9 31 24 84 10 05 23 71 11 26 45 21 8 62 46 17 9 36 25 97 10 05 24 84 11 26 43 40 8 62 44 29 9 36 27 10 10 05 26 53 11 26 36 17 8 62 36 78 9 36 32 18 10 10 31 61 11 32 34 44 8 62 35 00 9 36 34 44 10 10 33 31 11 32 33 38 8 67 34 44 9 36 5 65 5 29 33 87 11 32 32 88 8 6...

Page 15: ...roduce desired water temperature is on the lower axis If you wish to calculate the percentage of glycol on the basis of the temperature of the water produced enter from the right axis and on reaching the curve draw a vertical line which in turn will intercept all the other curves the points obtained from the upper curves represent the coef cients for the correction of the cooling capacity and inpu...

Page 16: ... 6000 7000 8000 9000 ANL100 ANL150 Useful static pressures with pump kPa ft h The static pressures stated here are at net of the pressure drops of the heat exchangers filter storage tank Therefore are to be consid ered USEFUL TO SYSTEM The static pressures are calcu lated in cooling mode WITH PRESENCE OF GLYCOL for static pressures useful to system PLEASE CONTACT COMPANY 0 6 70 13 40 20 10 26 80 3...

Page 17: ...he reference value by the corrective coefficient 12 2 EXPANSION VESSEL CALIBRATION Standard pre load pressure value of expansion vessel when empty is 1 5 bar 22psi maximum value is 6 bar 87psi Calibration of the vessel must be regulated using the maximum level difference H of the user see dia gram by using the following formula p calibration bar H m 10 2 0 3 For example if level difference H is eq...

Page 18: ... 77 0 45 0 59 0 62 4 67 3 72 2 72 7 69 7 61 5 49 6 14 PARAMETER CALIBRATION OF SAFETY AND CONTROL CONTROL PARAMETERS ANL min standard max Cooling set point C F 4 7 18 Heating set point C F 35 45 50 Defrosting mode C F 9 3 4 Total differential C F 3 5 10 Autostart auto CALIBRATION THERMOMAGNETIC ANL60HZ Models 60Hz Compressors magnet circuit breakers Pumps magnet circuit breakers Fan magnet circuit...

Page 19: ...n 1750 69 in 750 30 in Ø 34 138 80 3 in 1590 63 in 80 3 in Ø 9 40 1 6 in 20 8 in 750 30 in A D C B Mod A B C D VT 15 5 0 1 96 3 0 1 18 28 5 1 12 M10 VERS WEIGHTS BARYCENTRES KIT VT Gx Gy ANL100H A 800 381 640 15 ANL150H A 866 382 671 15 lbs mm in 5 4 in ...

Page 20: ...fety differences between the unit and other appliances or structures must be scrupulously respected so that the inlet and outlet air from the fans is free to circulate The unit must be installed by an enabled technician in complian ce with the national legislation in force in the country of desti nation respecting the minimum technical spaces in order to allow maintenance 15 1 1 SELECTION AND PLAC...

Page 21: ...ves in normal input in calibration valve output 4 A flow meter in inlet or a differential pressure switch inlet outlet 5 two thermometers in inlet and in outlet 6 Pump if not supplied with the machine 7 Expansion vessel if not sup plied with the machine 8 Safety valve if not supplied with the machine 9 Storage tank if not supplied with the machine It is necessary that the cooling unit water flow r...

Page 22: ......

Page 23: ...NOTES ...

Page 24: ...ns considered necessary for improving the product at any time AERMEC S p A 37040 Bevilacqua VR Italy Via Roma 996 Tel 39 0442 633111 Telefax 0442 93730 39 0442 93566 www aermec com info aermec com carta riciclata recycled paper papier recyclé recycled Papier carta reciclata recycled paper papier recyclé recycled papier ...

Reviews: