12

USING YOUR AIR SANITIZER

Power ON/OFF

The power icon            turns red when the 
product is plugged to a power outlet.  Unit is 
on standby mode but still OFF.

Gently pressing  the power button once 
produces an audible ring tone followed by 
the button turning green          .  Unit is now 
ON. 

      

to

n

n

ne

      

To turn the unit off  and return to standby 
mode, just press again          .

The unit then goes thru a 30 second system 
cycle that ends with the display panel 
showing whatever is the PM2.5 particle 
reading during start up.  

At this point  the button           lights up,  
indicating that the machine (by default) is 
now on Automatic Mode.

Mode Select

Pressing this  button in sequence will set 
the the machine thru the following modes 
of operation:

Adjusts the wind speed depending 
on the air quality detected.  

Auto

  

Negative ion generator is turned on.

Turbo  

  

Wind speed is adjusted to maximum.

Sleep     

  

Wind speed is adjusted to the lowest 
level and indication lamp is turned 
off .

Wind speed will not be controlled by 
the air quality sensor.

Speed Select

Pressing this button in sequence will cycle 
the machine into 3 diff erent wind speeds

Note that the fan motor speed will only 
be adjusted manually once this button is 
pressed (i.e., will not be controlled by air 
quality sensor.

Child Lock

While the unit is on, pressing gently this 
button for 5 seconds lights it up and locks 
the machine at its current confi guration.   

Once activated, all other function keys will 
be none operational.

To turn of the locked condition, press and 
hold button for 5 seconds.

Timer

Press to manually set the number of hours 
of operation (1 - 12).  Button lights up 
when activated.

A quick fi rst and second press sets the 
timer to 1 hr.  Each succeeding press adds 
an extra hour until 12 hrs is reached after 
which it goes back to zero.

To check for timer time remaining, press 
once  and the display panel will show the 
time left in minutes. 

Note:  Unit will automatically turn off  
when the front cover is removed or is 
improperly placed.

Summary of Contents for AER-PUR815

Page 1: ...USER MANUAL Power Air Sanitizer Please Read Manual Completely Before Using AER PUR815 Model...

Page 2: ...2 Power Air Sanitizer Thank you for purchasing the If you have any questions or concerns please reach out to us at aerione aerione com We hope you enjoy your new air sanitizer...

Page 3: ...age Contents 1 x Air sanitizer appliance 2 x Pre Filter pre installed 2 x Activated Carbon HEPA 13 Filter pre installed 1 x User Manual Specifications Voltage Input 110 120 VAC 60Hz Rated Power 85 W N...

Page 4: ...This may cause electrical shock or injury This product cannot replace normal ventilation equipment vacuum cleaners or kitchen fans Please do not use this product near gas appliances heating appliances...

Page 5: ...t used for a long period of time Before any electrical maintenance make sure to unplug the device to avoid the unit suddenly turning on Please plug the power cord securely into the power outlet to avo...

Page 6: ...nions that are released into the air These negatively charged ions get attached to air contaminants that are usually positively charged clumping together until the particles become heavy and fall to t...

Page 7: ...OW YOUR AIR SANITIZER A Side Cover B Air Intake C Air Particle Sensor D Control Panel E Air Quality Indicator Lamp F Air Outlet G Handle Grip H Roller Wheels F TOP FRONT LEFT SIDE RIGHT SIDE BACK D B...

Page 8: ...operate in either Automatic Turbo or Sleep Mode Manually adjust speed of operation Disables all other control keys Selects hours of machine operation Filter replacement reminder CONTROL KEYS STATUS MO...

Page 9: ...r the sanitizer exits sleep mode and will continue at automatic mode Good to Moderate Unhealthy Air Quality Indication AQI Surrounding air quality is monitored thru a built in floating particle sensor...

Page 10: ...all plastic packaging from filters 2 When re installing filters make sure that the 2 in 1 filter side with the pull tab are on top and facing out 3 Re install the two side covers 4 Note that the air...

Page 11: ...ere are no object to obstruct air flow thru the inlet or exhaust vents 2 Do not place in direct sunlight facing air conditioner vents or any heated surfaces to avoid the unit to warp deteriorate disco...

Page 12: ...to the lowest level and indication lamp is turned off Wind speed will not be controlled by the air quality sensor Speed Select Pressing this button in sequence will cycle the machine into 3 different...

Page 13: ...g of the surrounding air WiFi This air sanitizer may be managed from a mobile phone using the third party Smart Life app downloadable for free either from Apple App Store IOS or Google Play Android St...

Page 14: ...ress and hold the mode button for 5 secs and wait for the Wi Fi button to blink rapidly Note Only 2 4GHz Wi Fi networks are supported at the moment Confirm the Wi Fi rapid blinking on the machine then...

Page 15: ...n against dusts mites pollen ash pet dander hair soot and other similar in size floating particles Protection against odour and other nasty smells cigarette smoke molds gas pollutants as well as virus...

Page 16: ...eplace filters earlier than expected depending on where and how the air sanitizer is used ex when used in an environment with relatively high pollution Unless damaged the pre filter need not be replac...

Page 17: ...the machine allows real time detection of airborne micro particles allowing the fan motor to adjust in wind speed according to the condition To clean first remove the cover then wipe the sensor lens...

Page 18: ...the dusts taken in will result to the motor being damaged Unplug the unit when it will not be used over a long period Power is consumed even while in standby mode KEEPING THINGS CLEAN CONT Cleaning t...

Page 19: ...mell of air coming out of vent is unpleasant Filters too dirty and needs replacement Sanitizer has been running for a long time but has had no significant improvement in air quality Ensure that any pl...

Page 20: ...nd maintained according to the owner s manual guidelines This warranty extends only to personal use and does not extend to any product that has been used for industrial rental or any other use in whic...

Page 21: ...rated 77 City Centre Drive Suite 501 E Tower Mississauga ON L5M 6R1 Canada Email aerione aerione com Please have your order invoice and order ID or any proof of purchase ready before contacting Custom...

Page 22: ...22 NOTES...

Page 23: ...23...

Page 24: ...www aerione com...

Reviews: