background image

page 3 of 12 

1.Scetches 

 
1.1 Front of AB 200 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.1 Front of AB 500 / AB 1000 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(a) Power counter 
(kW/h)  

(b) device socket (max. 
8 A) 

(g) hose connector 
suction side D= 50 mm 
with filter 

(f) cable keeper with 
main cable (app. 3 m) 

(i) grip, hinged 

( c) Ammeter (see 6.3) 
(looks similar) 

(d) On-/Off-switch, 
iluminated 

( e) fuse for device 
socket ( 8 A) 

(h) hose connector 
pressure side D= 50 
mm 

(b) device socket (max. 
8 A) 

 

( c) Ammeter (see 6.3) 

(g) hose connector 
suction side D= 50 mm 
with filter 

(d) On-/Off-switch with 
motor protection 
 

( e) fuse for device 
socket ( 8 A) 

 

(f) cable keeper with 
main cable (app. 3 m) 

 

(i) Ventilation 
opening with fan 

(a) Power counter 
(kW/h)  

 

(h) hose connector 
pressure side D= 50

 

Summary of Contents for AB 1000 Series

Page 1: ...page 1 of 12 Instruction manual _____________________________________ Sound box with high pressure blower Series AB 200 AB 500 AB 1000 _____________________________________ valid 12 2010...

Page 2: ...Safety 5 6 5 Installation and transport 6 6 Operation 6 1 electrical connection 6 6 2 Putting into operation 7 6 3 Ammeter current power 7 8 7 Operating conditions 8 8 Technical data 8 9 9 Service Mai...

Page 3: ...ged c Ammeter see 6 3 looks similar d On Off switch iluminated e fuse for device socket 8 A h hose connector pressure side D 50 mm b device socket max 8 A c Ammeter see 6 3 g hose connector suction si...

Page 4: ...n order to save space you open simply the adhesive tape with a knife and you fold the carton 3 Mode of functioning features The sound box consists of a side channel blower model HB in following mentio...

Page 5: ...fety examination Dangers threaten in the case of operating error or abuse for the user for the machine and other real values for the efficient work of the machine All persons who have to do with the i...

Page 6: ...ng items must be checked Does the mains voltage coincide with the voltage of the appliance Adequate fusing of socket and supply system Has a residual current operated circuitbreaker r c c b been insta...

Page 7: ...During transgression of the permissible value a suitable measure is to be taken for lowering the current see 6 3 Ammeter current power 6 3 Ammeter current power The sound boxes of AB series have an a...

Page 8: ...dust In the case of doubtful operating conditions it is recommended to contact the Technical Department of Messrs AERIAL or a specialized dealer Using the sound box under inadequate operating conditi...

Page 9: ...le and must be repaired by an authorized specialized firm or the AERIAL GmbH Switch off the unit and pull the plug from the socket Dismantle the top cover Blow out device interior cautiously with comp...

Page 10: ...the power counter ATTENTION The appliance must be repaired by trained and expert personnel only In the case of interventions by unauthorized people any and all warranty claims shall become null and v...

Page 11: ...of 12 12 E circuit 12 1 AB 200 12 2 AB 500 AB 1000 Netzkabel Leistungz hler 000000 00 KW h Main cable M1 high pressure blower M2 cooling fan A Ammeter G device socket K1 power relay F1 Fuse for device...

Page 12: ...ed above is sound box with high pressure blower for cavity drying ready for connection Related standards EN ISO 12100 Safety of Machinery EN 61 000 Electromagnetic Compatibility EMC Basic Specificatio...

Reviews: