8 Transport and connection
Transport
WARNING!
Crushing as a result of
instability!
Transport the dehumidifier in an
upright position and secure it so that
it cannot tip over or slip.
Position the dehumidifier on a
stable, even surface.
WARNING! Risk of cuts and crushing
from incorrect handling during
transport
Do not reach into openings such as
air filters.
The dehumidifier must be
transported by two people using
appropriate lifting and transport
equipment.
Procedure
1. Make sure that the discharge hose
and the mains cable have been
disconnected from the appliance.
2. Transport the dehumidifier to where
it is going to be used.
Installing the dehumidifier
WARNING! Risk of dehumidifier
falling as a result of incorrect
assembly!
Only use the wall mount provided
and universal installation kit.
The dehumidifier must be installed
by two people.
Make sure that the wall is sound and
capable of bearing the load.
Requirements
The air must circulate freely. Do not
cover the air openings. There must be a
clearance of at least 100 cm in front of
the air outlet and the air filter.
There must be at least 10 cm between
the top of the wall mount and the nearest
object to allow the device to be mounted.
There must be at least 60 cm between
the bottom of the wall mount and the
nearest object.
Procedure
1. Remove and set aside the two
screws used to pre-assemble the
wall mount to the dehumidifier.
2. Use a spirit level to position the
wall mount horizontally and fix to
the wall using the universal
installation kit as shown in fig. 5.
Drilled hole Ø = 8 mm.
3. Hang the dehumidifier on the
bracket of the wall mount.
4. Screw the dehumidifier to the wall
mount using the two screws from
step 1 to secure the device so that it
does not fall.
Connecting the discharge hose
ATTENTION!
Inadequate appliance
output!
Do not bend the discharge hose.
Do not place any objects on the
hose.
Procedure
1. Attach the discharge hose on the
back of the device to the discharge
nozzle and secure with the hose
clamp.
2. Run the discharge hose away from
the dehumidifier to a drain
(maximum height difference: 3 m).
Electrical connection
Procedure
1. Make sure that the supply voltage is
the same as the connection voltage
in the technical data.
2. Provide an adequate fuse for the
socket and the power supply.
3. Install an earth leakage circuit
breaker in damp rooms and building
sites.